25
System Settings
To configure alarms
1.
In the left-hand menu, select
Alarm configuration
as shown in figure 5.11.
2.
Under Alarm Switch, select
On
or
Off
to enable or disable the alarm function.
3.
Under Alarm Type, select the alarm type,
Normal close
or
Normal open
, corresponding to
the alarm application.
4.
Under Alarm Output, define the normal output signal status as
high
or
low
according to
the current alarm application.
5.
Check the boxes
Send Alarm Message by FTP
or
Send Alarm Message by E-Mail
as
appropriate to your system.
please note
Make sure the SMTP or FTP configuration has been completed as described
in sections 4.5 Mail and 4.6 FTP.
5.8. Motion
Detection
The
Motion detection
function enables the camera to trigger an alarm when motion volume
in a detected area reaches or exceeds a configured sensitivity threshold value.