5. TEMPERATURE - this tab allows you to change the
temperature of the print surface. Press + to increase
the temperature or - to decrease it.
Mechanics
Temp.
Advanced
Print surface 36.6°C
+
-
The TEMPERATURE panel.
After changing the temperature, the difference
between the default temperature and the modified
temperature will be displayed on the screen.
Allowed range of change: from -5.0 [°C] to +5.0 [°C]
Mechanics
Temp.
Advanced
Print surface 36.6°C
User offset: +0.5°C
+
-
Showing the temperature offset.
6.
Advanced - this tab you can find:
•
SELECT WI-FI - Status of the printer’s connection to
the Wi-Fi network. The name of the currently chosen
network is displayed, to the right of the “Select Wi-Fi”
option.
•
SIMPLE MODE - allows you to switch from advanced
mode to simple mode.
•
COPY LOGS TO USB - allows you to copy the logs from
the printer to the USB flash drive (and e.g. send to the
Sinterit Support, in case of problems)
•
ABOUT - displays the printer’s basic information, such
as: model name, version and serial number
Mechanics
Temp.
Advanced
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
Select Wi-fi
fubar (CONNECTED)
Simple Mode
Copy logs to USB
About
The ADVANCED panel.
7. After pressing the SIMPLE MODE button in the
ADVANCED panel, a window will appear with
information about the possibility of starting each
subsequent printing with Advanced Mode.
•
If you want to use Advanced Mode once, uncheck the
box and press the SWITCH TO SIMPLE MODE button.
•
If you want to use Advanced Mode by default, check
the box and press the SWITCH TO SIMPLE MODE
button
Mechanics
Temp.
Advanced
√
Always start in advanced mode
Back
Switch to
Simple Mode