41
Function
Code
Default
Property
Setting
Range
Name
Group F0C Serial Communication Function
1
0~247 (0 is the broadcast address)
Local
communication
address
F0C.00
4
Communication
baud ratio setting
F0C.01
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
1
F0C.02
0: No check (N, 8, 1) for RTU
1: Even check (E, 8, 1) for RTU
2: Odd check (O, 8, 1) for RTU
3: No check (N, 8, 2) for RTU
4: Even check (E, 8, 2) for RTU
5: Odd check (O, 8, 2) for RTU
Digital bit
checkout setting
5ms
0~200ms
Answer delay
F0C.03
○
○
○
○
Function Parameters Table
F0B.09
F0B.10
F0C.12~200%
0.1~60.0s
150%
0.0s
○
○
0x00~0x11
LED ones
0: Action under fault undervoltage
1: No action under fault undervoltage
LED tens
0: Action during the automatic reset
1: No action during the automatic
reset
○
0x00
Output terminal
action during
fault
F0B.11
Overload pre-alarm
detection
Overload pre-alarm
detection time
0x000–0x111
LED ones:
0: 3PH and 2PH modulation
1: 3PH modulation
LED tens:
○
0x00
PWM
selection
F0B.12
○
Fault time of
communication
overtime
F0C.04
0.0 (invalid), 0.1~60.0s
0.0s