31
Function
Code
Name
Default
Property
Setting
Range
○
○
○
STOP/RESET
stop
function
selection
0: Only valid for
keypad
control
1: Both valid for
keypad
and
terminal
control
2: Both valid for
keypad
and
communication
control
3: Valid for
all
control
modes
F07.03
Shifting
sequence
selection of
S
commands
F07.02
F07.04
F07.05
0x00~0x1F
Bit0: Analog AI1 value
Bit1: Motor
overload percentage
Bit2: AC drive overload percentage
Bit3: Ramp frequency setting value
(Hz
is
ON)
Bit4: Linear
speed
Bit5~BIT15: Reserve
Parameters
state 1
Parameters
state 2
0x0000~0xFFFF
Bit0: Running
frequency (Hz
ON)
Bit1: Set frequency (Hz
blinking)
Bit2: Bus
voltage
Bit3: Output
voltage
Bit4: Output current (A
ON)
Bit5: Running
speed
Bit6: Output
power
Bit7: Output
torque
Bit8: PID
reference
value
Bit9: PID
feedback
value
Bit10: Input
terminal state
Bit11: Output
terminal
state
Bit12~BIT14:Reserve
Bit15: The current stage in
Multi-stage speed/PLC
0
0x03FF
0x00
When F07.01=6, set the shifting
sequence of running command
channels.
0: Keypad control→terminals control
→communication control
1: Keypad control←→terminals control
2: Keypad control←→
communication control
3: Terminals control←→
communication control
Function Parameters Table
○