51
For example
:
The parameter F04.13 is not stored in the EEPROM, and the address is
represented as 0x040D
;
The parameter F04.13 is stored in EEPROM , and the address is represented
as 0xF40D
;
Function parameters set permissions and function code attributes related
parameters, such as read-only parameter is not writable, the operation cannot
be changed in the running also cannot be written.
When read the function code parameters, user can only read the maximum of
16 consecutive address parameters.more than 16, the AC drive will return the
illegal data.
The password is set by the user, in the case without decryption, all of the
parameters cannot write. User password and parameter autotune cannot via
communication to write. Otherwise, the AC drive will return the fault information.
When writing function parameter, each can only write a parameter. Users should
pay attention to the setting value that cannot exceed the set range of function
parameters.
Read of both EEPROM address and RAM address are valid.
6.3 Special register address definitions
Register
R/W
Function
Add
Setup description
Control
Register
2000H
Control
Word register
W
0001H: Forward running
0002H: Reverse
running
0003H: Forward
jog
0004H: Reverse
jog
0005H: Deceleration
stop
0006H: Free
stop
(
Emergency Stop
)
0007H: Fault
reset
0008H: Jog
stop
0009H: Pre-excitation
Rs485 Communication protocol