40
Function
Code
Default
Property
Setting
Range
Name
Group F0B Protective Parameters
Output phase
loss protection
F0B.01
F0B.00
F0B.02
F0A.37
Multi-stage time
unit
Frequency decrea-
sing ratio at sudden
power loss
Frequency decrea-
sing at sudden
power loss
F0A.36
PLC
restart mode
selection
0
1
0: Invalid
1: Valid
0: Invalid
1: Valid
10.00Hz/s
0.00~50.00Hz/S(General Motor)
0: seconds
1: minutes
0
0
0: Restart from the first step.
1: Continue to run from the stop
frequency.
◎
◎
◎
◎
◎
1
0: Invalid
1: Valid
Over-voltage stall
protection
F0B.03
◎
Function Parameters Table
0.0~500.00Hz/S(HF Motor)
100.00Hz/s
○
◎
◎
120~150%
(Standard bus voltage 220V)
120~150%
(Standard bus voltage 380V)
130%
120%
0: Current-limiting is invalid
1: Current-limiting is valid
1
50.0~200.0%
F0B.04
Voltage
protection of
over-voltage stall
F0B.07
F0B.05
F0B.06
Current limit
action selection
Automatic current
limit
Frequency-
decreasing ratio
during current limit
0x000
F0B.08
Overload pre-alarm
of motor/inverter
165%
10.00Hz/s
0.00~50.00Hz/S(General Motor)
◎
0.0~500.00Hz/S(HF Motor)
100.00Hz/s
0x000~0x111
LED ones
:
0: Overload pre-alarm of the motor,
relative to the rated current of the motor
1: Overload pre-alarm of the inverter,
relative to the rated current of the inverter
LED tens
:
0: The inverter continues to work after
underload pre-alarm
1: The inverter continues to work after
underload pre-alarm and the inverter
stops to run after overload fault
◎