display will resume to original setting temperature.
Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired:
◆
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user
individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for
confirmation.
Note:
In the above presetting or enquiry procedure, if continuously within 10s, there is no button pressed, the
sleep curve setting within 10s, there is no button pressed, the sleep curve setting status will be automatically quit
and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF" button,
"Mode" button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
10)
TEMP:
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature. When
the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying status is
changed from other status to"
",displays the ambient temperature, 5s later or within 5s, it receives other
remote control signal that will return to display the setting temperature. If the users haven't set up the temperature
displaying status, that will display the setting temperature.
11)
QUIET:
Press this button, the Quiet status is under the Auto Quiet mode (display "
"signal ) and Quiet mode
(display "
" signal) and Quiet OFF (there is no signal of "
"displayed),after powered on, the Quiet OFF is
defaulted.
Note:
the Quiet function cannot be set up in Fan and Dry mode; Under the Quiet mode
(Display "
" Under the Quiet mode (Display "
" signal), the fan speed is not available.
12)
CLOCK :
Press CLOCK button, blinking
. Within 5 seconds, pressing
+
or
-
button adjusts the present time.
Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0.5 second and
then by 10 minutes every 0.5 second. During blinking after setting, press CLOCK button again to confirm the
setting, and then
will be constantly displayed.
13)
T-ON/ T-OFF:
Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button
again.
After press of this button,
disappears and "ON "blinks. 00:00 is displayed for ON time setting. Within
5 seconds, press + or - button to adjust the time value. Every press of either button changes the time setting by 1
minute. Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes. Within 5
Seconds after setting, press TIMER ON button to confirm.
Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply press the button
again. TIMER OFF setting is the same as TIMER ON.
14)
TURBO:
22
Содержание MS-E48AIN
Страница 1: ...HIGH POWER MULTI SYSTEM SERVICE MANUAL EN MS E48AIN MS E56AIN Outdoor unit ...
Страница 11: ...CONTROL 1 OPERATION FLOWCHART 6 ...
Страница 13: ...1 2 Heating Operation 8 ...
Страница 47: ... Outdoor unit higher than indoor unit DB DB DB DB 42 ...
Страница 70: ...Malfunction display High Pressure Protection 2 1 65 ...
Страница 87: ...PARTS GUIDE MS E48AIN MS E56AIN DB2 19SB DB3 19SB DB5 16AF HIGH POWER MULTI SYSTEM ...
Страница 88: ...Exploded view of unitMS E48AIN ...
Страница 91: ...Exploded view of unitMS E56AIN ...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......