4.1
Precaution for Installation
The installation of the air conditioner must be in accordance with the national and local laws and
regulations.
The quality of the installation will affect the capability of air conditioner directly. The installation
should be left to the appointed service center. Please contact your dealer after purchasing this machine.
Professional installation workers will provide installation and test services according to the installation
manual.
The air conditioner should not install in this place where the small animals exist, because they may
cause malfunctions, smoke or fire.
Please keep the area around the unit clean.
4.2
Names of Main Parts
a) DB3-16AF b) DB5-16AF
NO.
①
②
③
④
Name
Gas piping of indoor unit
side
Liquid piping of indoor
unit side
Hanger metal
Gas piping of outdoor unit
side
NO.
⑤
⑥
⑦
⑧
Name
liquid piping of outdoor
unit side
Electrical box
Drain hole
Electrical equipment plate
4.3
Selection of Installation Location
The DB module is for indoor use. If installing in the outdoors, the location must be away from wind and
rain. Otherwise, it maybe causes water leakage, electric shocks or fire etc.
The
DB module must be installed on a firm and solid support
which can withstand the weight of the
module and the mounting surface must be horizontal plane. The DB module can be chosen to install in
the ceiling,
such as the ceiling of parlor, corridor, balcony,
storeroom
and etc
There is enough space for the installation and maintenance.
Avoid direct sunlight or other heat sources exist
Do not install in location that is hot or humid for long periods of time.
Avoid the DB module installed in the bedroom and study, where these places need to be quiet
DB module cannot be installed in the place of inflammable and explosive materials and severe dust,
smoke and the other air pollution, such as the kitchen.
There is enough space to install drainage pipe, so that the condensed water can be discharged.
Caution!
Installation at the following places might lead to the air conditioner malfunction. If it is unavoidable, please
contact the appointed service center.
4 DB MODULE INSTALLATION
36
Содержание MS-E48AIN
Страница 1: ...HIGH POWER MULTI SYSTEM SERVICE MANUAL EN MS E48AIN MS E56AIN Outdoor unit ...
Страница 11: ...CONTROL 1 OPERATION FLOWCHART 6 ...
Страница 13: ...1 2 Heating Operation 8 ...
Страница 47: ... Outdoor unit higher than indoor unit DB DB DB DB 42 ...
Страница 70: ...Malfunction display High Pressure Protection 2 1 65 ...
Страница 87: ...PARTS GUIDE MS E48AIN MS E56AIN DB2 19SB DB3 19SB DB5 16AF HIGH POWER MULTI SYSTEM ...
Страница 88: ...Exploded view of unitMS E48AIN ...
Страница 91: ...Exploded view of unitMS E56AIN ...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ...Exploded view of distribution box DB5 16AF ...