If you want to check that the peripheral system is transmitting data to the SN90,
select
Monitor
.
The
Port Monitor
dialog box provides one text box for incoming messages (
Rx
Data
), and one for outgoing messages (
Tx Data
). Use these boxes and your
knowledge of the data communication to investigate the datagrams. The
Port
Monitor
dialog box is a tool for debugging purposes. It is neither required nor
intended for normal operation of the SN90.
9
Type a custom name to identify the interface in other dialog boxes.
10
Select which datagram(s) you want to import from the sensor.
11
If relevant, specify a dedicated talker ID.
12
Provide the accurate physical location of the sensor (or its antenna) with reference
to the vessel’s coordinate system.
The position of certain sensors must be defined as an
offset
to the
Ship Origin
in the
coordinate system to maximize performance. These offset values are all required
to allow the SN90 to give you as accurate information as possible. The degree of
accuracy offered by the SN90 is directly related to the accuracy of the information
you enter on the
Sensor Installation
page.
a
Select the offset value on the X axis (fore-and-aft direction) from the
Ship
Origin
. Adjust with a positive value for X if the sensor is located ahead of the
ship origin.
b
Select the offset value on the Y axis (athwartship) from the
Ship Origin
.
Adjust with a positive value for Y if the sensor is located on the starboard
side of the ship origin.
c
Select the offset value on the Z axis (vertical) from the
Ship Origin
. Adjust
with a positive value for Z if the sensor is located under the ship origin.
13
Select
Add
to save the new sensor interface you have defined.
The sensor interface is added to the
Installed Sensors
list on the
Sensor Installation
page.
14
At the bottom of the dialog box, select
Apply
to save your settings.
15
Continue your work in the
Installation
dialog box, or select
OK
to close it.
Further requirements
On the left side of the
Installation
dialog box, select
Sensor Configuration
. Define the
priority of the datagrams, and set up relevant configuration parameters.
Related topics