134
381295/B
• The communication parameters required for the sensor interface are known.
Context
The
I/O Setup
page provides two lists; one for serial ports and one for Ethernet
(LAN) ports. Each list is supported with a set of functions to set up and monitor the
communication ports. Select the port you want to work with and then select one of
the buttons below the list.
Tip
The
Sensors
page in the
BITE
(Built-In Test Equipment) dialog box provides an overview
of all the communication lines and sensors in use. All relevant status information is
provided. You open the
BITE
dialog box from the
Setup
menu.
When you work in the
Installation
dialog box, you must always select
Apply
to save the
changes made on a page. You must do this before you continue working on a different
page.
Procedure
1
Open the
Setup
menu.
2
On the
Setup
menu, select
Installation
.
Observe that the
Installation
dialog box opens. This dialog box contains a number
of pages selected from the menu on the left side.
3
On the left side of the
Installation
dialog box, select
I/O Setup
.
4
Observe that the available serial and network interface ports on the Processor Unit
are listed.
5
Set up the relevant serial or Ethernet (LAN) communication parameters.
a
Select the interface port you wish to set up.
b
Select
Setup
below the list to open the
Serial Port Setup
or
LAN Port Setup
dialog box.
c
Set up the relevant serial or Ethernet (LAN) communication parameters.
The communication parameters defined for
NMEA 0183
are:
•
Baud Rate
: 4800 bit/s
•
Data Bits
: 8
•
Parity
: None
•
Stop Bits
: 1
Some instruments may offer other parameters and/or options. You must always
check the relevant documentation provided by the manufacturer.
d
Select
OK
to save the selected settings and close the dialog box.
Simrad SN90 Operator Manual