Installation / Electrical / Operation

4

NOTICE: 

Drill a 1/8" (3.2 mm) hole in discharge pipe just

above pump body but below the check valve to prevent air
locks. 

5.

Power Supply:

The pump is designed for 115 V., 60 Hz.,

operation and requires a minimum 15 amp individual branch
circuit. Both the pump and switch are supplied with 3-wire
cord sets with grounding-type plugs. The switch plug is
inserted directly into the outlet and the pump plug inserts
into the opposite end of switch plug.

Hazardous voltage. Can shock, burn or cause

death. 

Pump is supplied with a grounding conductor and

grounding-type attachment plug. To reduce the risk of elec-
tric shock, be certain that it is connected only to a properly
grounded, grounding type receptacle such as a grounded
water pipe or a properly grounded metallic raceway or
ground wire system. Ground terminal on pump cord plug is
provided for your protection. DO NOT REMOVE!
A ground fault circuit interrupter is recommended for use
with any electrical appliance submerged in water. For instal-
lation of such a circuit, consult a licensed electrician.

6. After the piping and the check valve (if needed) have been

installed, the unit is ready for operation

7. Check the operation by filling the sump with water and

observing pump operation through one complete cycle.

Risk of flooding. Can cause personal injury

and/or property damage.

Failure to make this operational

check may lead to flooding and premature failure.

OPERATION / MAINTENANCE

Risk of electric shock. Can burn or cause death.

Before attempting to check why unit has stopped operating, dis-
connect the power from the unit. Do not handle the pump with
wet hands or when standing on wet or damp surfaces, or in
water.
1. The shaft seal depends on water for lubrication and cooling.

Do not operate the pump unless it is submerged in water as
the seal may be damaged if allowed to run dry.

2. The motor is equipped with an automatic reset thermal pro-

tector. If the temperature in the motor should rise unduly, the
switch will cut off all power before damage can be done to
the motor. When the motor has cooled sufficiently, the
switch will reset automatically and restart the motor. If the
protector trips repeatedly, unplug the pump and remove it;
check for cause of difficulty. Low voltage, extension cords,
clogged impeller, very low head or lift, etc., could cause
cycling.

Risk of sudden starts. Can cause electrical shock

and personal injury.

The pump motor is equipped with automat-

ic resetting thermal protector and may restart unexpectedly. 
3. The pump will not remove all water. 

NOTICE:

For continuous operation, water depth must be at

least 5" (13cm) to prevent motor overheating.

AUTOMATIC FLOAT SWITCH -

INSTALLATION

1. Install the pump following the installation and operating

instructions.

2. The automatic float switch is sealed and factory adjusted for

most home sumps. See Page 3 for the switch settings.

NOTICE:

Minimum recommended turn-off level above pump

base is 5” (13cm).

3. Be sure the horizontal float switch clearance is 8” (203mm).

For best performance of pumps with tethered switches, the
sump diameter and sump depth should be at least 12”
(305mm). 

Risk of flooding. Can cause personal injury

and/or property damage. 

May lead to improper operation or

premature failure. If a flexible discharge hose is used, the
pump may move when the motor starts. If the switch hits the
side of the sump, the switch may stick and prevent the pump
from starting. Make sure the pump is secured so it cannot
move around in the sump.

4. Plug the piggyback switch cord into a 115V AC outlet. Then,

plug the pump into the plug on the piggyback switch cord.
Do not allow the cord to interfere with the float control
motion or to drape over the pump motor. With electrician's
tape or cable ties secure the cord to the discharge pipe for
cord protection.

FLOAT SWITCH - 

OPERATIONAL CHECK 

1. Fill the sump with the correct amount of water to check the

operation and tightness of the connections. During the first
automatic cycle, it may take 30 seconds or more before the
pump is primed and pumping. The pump will start as indi-
cated in the “Motor, Switch and Cord Specifications” Table,
Page 3.

2. Check the turn-off position. The pump will stop approximate-

ly as indicated in the “Motor, Switch and Cord Specifications”
Table, Page 3.

3. If the pump does not operate check the electrical service.

NOTICE:

The float switch tether length is set at the factory. It

is 3-1/2” (89mm). Do not change the tether length of the
float switch. Float must be able to swing through its complete
arc without interference.

Float Switch Tether Length

Содержание 2975PC

Страница 1: ...le 1 800 468 7867 Fran ais Pages 7 11 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 12 16...

Страница 2: ...d by a qualified electrician 13 Make certain the power source conforms to the requirements of your equipment SIMER warrants to the original consumer purchaser Purchaser of its products that they are f...

Страница 3: ...with salt water or brine will void warranty Pump water only with this pump PERFORMANCE INSTALLATION 1 Install the pump in a sump pit with a minimum diameter of 12 305mm Construct the sump pit of tile...

Страница 4: ...y and restart the motor If the protector trips repeatedly unplug the pump and remove it check for cause of difficulty Low voltage extension cords clogged impeller very low head or lift etc could cause...

Страница 5: ...ze Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company or hydro authority Defective motor Replace pump Defective float s...

Страница 6: ...7 1 3 4 5 2 6 7 4073 0901 Key Part No Description Qty 2975PC 1 Power Cord 1 227 264 B TSU 2 Float Switch 1 PS117 144P 3 Motor Assembly 1 4 Impeller 1 416 018 5 Volute 1 6 Suction Housing 1 772 010 7 S...

Страница 7: ...ne comporte que 2 trous elle devra tre rem plac e par une prise de courant 3 trous dont un de mise la terre De plus elle devra tre pos e conform ment aux codes et aux r gle ments en vigueur Cette pom...

Страница 8: ...pour pomper de l eau sal e ou de la saumure Pomper de l eau sal e ou de la saumure annulera la garantie Ne pomper que de l eau avec cette pompe D BITS INSTALLATION 1 Installer la pompe dans un puisard...

Страница 9: ...t tr s basse etc risquent de causer cet incident Risque de d marrages brusques pouvant causer des secousses lectriques et des blessures corporelles Le moteur de la pompe est prot g par un dispositif d...

Страница 10: ...x Interrupteur flotteur d fectueux Remplacer l interrupteur flotteur La pompe ne s arr te pas Interrupteur flotteur d fectueux Remplacer l interrupteur flotteur Refoulement obstru D poser la pompe et...

Страница 11: ...0 546 7867 1 3 4 5 2 6 7 4073 0901 R f D signation Qt 2975PC 1 Cordon lectrique 1 227 264 B TSU 2 Interrupteur flotteur 1 PS117 144P 3 Moteur 1 4 Impulseur 1 416 018 5 Volute 1 6 Carter d aspiration 1...

Страница 12: ...re spondan No se ha investigado la operaci n de esta bomba para su uso en reas de piscinas de nataci n 12 Se recomienda usar un disyuntor de escape a tierra con todo aparato el ctrico sumergido en agu...

Страница 13: ...a garant a Bombee solamente agua con esta bomba DESEMPE O INSTALACI N 1 Coloque la bomba en un foso de sumidero con un di metro m ni mo de 12 305 mm Construya el foso de sumidero de baldosas hormig n...

Страница 14: ...se dispara repetidamente desenchufe la bomba y s quela verifique cu l es la causa del problema Baja ten si n cordones de alargue impulsor obstruido muy poca altura o alza etc puede provocar los ciclos...

Страница 15: ...lace el interruptor de flotador La bomba arranca y se Interruptor de flotador defectuoso Reemplace el interruptor de flotador detiene con demasiada Descarga restringida Saque la bomba y limpie la bomb...

Страница 16: ...073 0901 Clave Descripci n de No la pieza Cant 2975PC 1 Cord n el ctrico 1 227 264 B TSU 2 Interruptor de flotador 1 PS117 144P 3 Unidad del motor 1 4 Impulsor 1 416 018 5 Voluta 1 6 Caja de aspiraci...