66
On the bottom line the name of the currently displayed function appears; if the text is too long the line will be scrolled up to the end of the text. The
items follow the order shown in Table 12.
Menu
Submenu
Values
General Settings
Stove Type
Stove type name
Reset Service Time
Hours elapsed since the last maintenance
operation
Pellet Level Sensor
On / Off
Eco Menu
Waiting On
0 ÷ 30 min
Waiting Off
0 ÷ 30 min
Delta Temp.
0 ÷ 10 °C
Pellet Feeder Menu
Pellet Feeder Brake (fuel feeder motor quick
stop option)
On / Off
Duration at Min Power (on time @ min. pw.)
0.10 ÷ 12.00 sec ** (step 0.05sec)
Duration at Max Power (on time @ max. pw.)
0.10 ÷ 12.00 sec **(step 0.05sec)
AUX. Output (2nd fuel feeder device)
On / Off
Periods Ratio (on/off duty cycle)
1 ÷ 100
Percentage Factor (on time correction)
-10 ÷ +100
Combustion Airflow Menu
RPM Control
On / Off
Airflow at Min Power
0 ÷ 400 lpm
Airflow at Max Power
0 ÷ 400 lpm
RPM Min Power
300 ÷ 2750 rpm
RPM Max Power
300 ÷ 2750 rpm
Motor Type
0 ÷ 3
Second Extractor Menu
Enable
On / Off
Ignition 1
0 ÷ 30
Ignition 2
0 ÷ 30
Shut down 1
0 ÷ 30
Shut down 2
0 ÷ 30
Level 1 ***
0 ÷ 30
Level 5 ***
0 ÷ 30
Hydro Menu
Hydro Mode
On / Off
Water Pressostat
On / Off
Max Water Pression
2,5 ÷ 4,7 Bar
Accumulator (water storing tank)
On / Off
Modulating Pump (on/off temp. dependent
timed mode of operation)
On / Off
Temp. On Pump
40 ÷ 80 °C
Secondary Fluxmeter
On / Off
Hydro Shutdown
On / Off
Hydro Independent
On / Off
Water Temp. Hysteresis
4÷ 15
Sanitary Gain (H.D.W. temp. control loop gain)
-10÷ +10
Ignition Menu
Fumes Temp. On (heater fired up smoke temp.
threshold)
0 ÷ 150 °C
Fumes Temp. Off (smoke shutdown end temp.
threshold)
10 ÷ 290 °C
Pre-Startup 1 Duration (warm-up time 1)
0 ÷ 300 sec
Pre-Startup 2 Duration (warm-up time 2)
0 ÷ 300 sec
Warm Pre-Startup Duration (firing up time with
a still hot heater)
0 ÷ 300 sec
Ignition Duration
0 ÷ 3600 sec
Fire On Duration
0 ÷ 3600 sec
Photoresistor
On / Off
Alarm Menu
Combustion Airflow Pre-Alarm Duration
180 ÷ 14400 sec