64
SETTINGS
2.5.4.4
The settings menu, like the main menu, includes a set of data and items; it works in the same way as described for the main menu.
In Table 10 the various functions are listed in the same order as they appear on the display, along with their values.
Function
Value
Language
It–En–Fr–Es–De–Pt–Nl-Gr
Eco
On / Off
Back Light
On – 1200” (10” steps)
Tones
On / Off
°C/°F
Auto/ °C/ °F ( See § “°C - °F” at page )
Pellet Recipe (pellet feeder on time correction)
See § “PELLET FEEDER CORRECTION” at page
Thermostat *
On / Off
Charge Pellet (auger feeder activation) **
See § “FUEL FEEDER FILLING FUNCTION” at page
Cleaning **
See § “BURNER POT CLEANING” at page
Start Pump ***
See § “PUMP ACTIVATION” at page
Setting functions list
Table 10
*
If the “HYDRO” mode is active (See Table 12), the function Thermostat is displayed only if the Storing tank is disabled.
**
May be displayed only if the heater is OFF.
*** May be displayed only if the HYDRO mode is active and the heater is OFF.
BACKLIGHTING
The backlighting option allows the user to set the time and the backlighting level used in the START screen. Choosing On, the display will then be
kept lighted up all the time; the other items set the time when the backlighting is dimmed down.
°C - °F
The “°C / °F” option allows the user to select the measuring unit to be used for any temperature value displayed.
The default setting is Auto; such setting chooses the measuring unit to fit the heater type in use (for European or U.S.A. market).
When the Set button is pressed (key #3), the value shown on the top line starts blinking to let the user being informed that it may now be changed,
while “
Set
” is replaced by “
Ok
”; the two bottom keys may be two arrows or change in
+/-
, depending on the displayed data type, and they are used
to increase or decrease the data value. The new value is confirmed by pressing button
Ok
(key #3), while the display reverts to the previous screen
(unflashing).
PELLET FEEDER CORRECTION
The “Pellet Recipe” option allows the user to modify the pellet feeder working duty cycle.
Function
Value
Temporary States Activations
-5 ÷ +5
Power States Activation
-5 ÷ +5
List of pellet feeder correction functions
Table 11