CLEANING (Fig. 60)
2.5.6
Cleaning operations must be carried out at
regular intervals and only when the boiler
is cold.
Combustion residuals collect in the remov-
able drawer that must be emptied before
starting the boiler. To remove all combus-
tion residuals, use an ordinary aspirator and
verify that all the ashes inside the combustion
chamber have been completely removed.
The aspirator can also be used to clean the
pellet grille.
To clean the fume ducts inside the boiler
body, use a wiper.
ATTENTION: if the generator is switched
off for long periods of time (above 15
days), it is necessary to empty the 80 kg
pellet container in order to prevent the
pellets from absorbing excessive humid-
ity, which could affect the operation of
the boiler. A high amount of humidity in
the pellets could cause them to pulverize,
increase the amount of residuals in the
brazier and obstruct the pellet feeding
system.
ANNUAL MAINTENANCE
2.5.7
For optimum performance, it is advisable
to have the boiler inspected accurately
and thoroughly by qualified personnel at
least once every season.
Before performing maintenance opera-
tions, verify that the boiler is cold and has
been disconnected from the mains.
Fig. 60
Removable
drawer
Pellet grille
ACCESSORIES
2.5.8
ACCESSORY KIT:
-
5197500
200-litre
PELLET
TANK
-
5197510
300-litre
PELLET
TANK
-
5197520
500-litre
PELLET
TANK