70
By pressing the key
info
(key #1) the display shows a brief description of the problem occurred (Fig. 59).
e s c
A L A R M
A 0 1
C a l l
A s s i s t a n c e
ALARM screen
Fig. 59
On the top line “info” is replaced by “
esc
”, while ALARM is steady on; on the bottom line a brief description of the problem is scrolled. The display
reverts back to the previous screen by pressing the key
esc
(See Fig. 57). If no other key is pressed for 60 seconds, the display reverts back to the
start screen.
The Table 16 shows a list of the alarm codes, their names and useful informations about how to reset them.
Code
Alarm type
Informations
A01
Ignition Failed
Clean Brazier and Restart
A02
Flame Shut Down
Fill Pellet Tank
A03
Pellet Tank Over-Temperature
See instruction manual
A04
Fumes Over-Temperature
See instruction manual
A05
Fumes Pressure Switch Alarm
NON PREVISTO
A06
Combustion Airflow Alarm
NON PREVISTO
A07
Door Open
NON PRESENTE
A08
Fumes Extractor Error
Call Assistance
A09
Fumes Temp. Sensor Error
Call Assistance
A10
Pellet Igniter Error
Call Assistance
A11
Pellet Feeder Error
Call Assistance
A13
Electronic MotherBoard Error
Call Assistance
A15
Pellet Level Alarm
Check Pellet Level
A16
Water Pressure Out of Range
Restore the Correct System Pressure
A18
Water Tank Over-Temperature
INTERVENTO TERMOSTATO DI SICUREZZA.
VEDI LIBRETTO ISTRUZIONI
Alarm list
Table 16