GENERAL FEATURES
Wall installation is foreseen although the
device for battery pack replacement can be
removed.
INSTALLATION
1) The remote control panel must be
installed at a height of about 1.5 meters
from the ground, as far as possible from
heat sources and from doors and/or
windows. There is a special hole at the
back of the adapter base for connection
of the electric wires.
IMPORTANT: Switch off power to the
plant before connecting the wires.
2) Remove the adaptor from the remote
control panel, by pressing with the fin-
gers on the crescent shaped part (fig. 2).
3) Unscrew the two screws on the adaptor
and fix the lower shell of the same to the
wall.
4) Connect the terminal block to the adap-
tor, taking care to follow the diagram in
fig. 4. The connections are not polarised.
5) Insert the batteries into the special com-
partment in the back of the remote con-
trol panel.
6) Using a ball point pen, press the button
(reset)
on the front of the control panel,
accessible by opening the lower hatch.
7) Close the adaptor cover and apply the
terminal of the remote control panel to
it (fig. 3).
REMOTE CONTROL 582 HRC
Fig. 1
Protection degree
IP20 (in the case of wall installation)
Maximum overall dimensions (mm)
L=132 x H=105 x P=43
LCD area visible LCD (mm)
83 x 55
Power supply voltage
24 Vdc
Buffer batteries
4 alkaline pen batteries LR6 AA - 1.5V
Working temperature range (°C)
0 ÷ 40
Storage temperature range (°C)
10°C ÷ 50°C
Humidity
max 95 % at 40°C
Back-up autonomy
≥
1 year
Use
in sunlight/artificial light
Connection
max 20 m
Reading resolution
0.1°C between 0°C and 40°C
Maximum reading error
1°C between 0°C and 40°C
Setting regulation range (°C)
5 ÷ 30
Min. regulation range (°C)
0 ÷ 25
Data updating interval
1s
Monitoring/control interval
1s
TECHNICAL DATA
Fig. 2
67
USER’S INSTRUCTIONS
WARNINGS
- In the case of breakdown or faulty functioning of the appliance, switch it off and make no attempt whatsoever to repair it, and do not pro-
ceed with any direct intervention.
- Apply only to authorised technical personnel. Installation of the boiler or any other assistance or maintenance work must be carried out
by qualified personnel. Tampering with devices sealed by the constructor is absolutely forbidden.
- Obstructing the aspiration grills and the air vents of the room where the appliance is installed is asolutely forbidden.
-
The constructor shall not be responsible for any damages deriving from incorrect use of the appliance.
Fig. 3
NO
YES