77
IT
ES
ENG
GAS TRANSFORMATION
Only. contact. authorised. technicians. if.
transformation. to. another. gas. is. requi-
red.
CLEANING AND MAINTENANCE
Scheduled generator maintenance must
be performed annually by authorised
technicians.
The boiler is supplied with a power cord
which, if replacement is required, must
be ordered from SIME.
“DEWY EQUIPE P100 BOX”
SINGLE MODULE MALFUNCTIONS
–. Ignition lock (fig..3)
. If.the.burner.does.not.light.the.red.led.(
).turns.on..To.attempt.ignition.again,.
rotate.the.selector.knob.to.( ).and.rele-
ase.it.immediately.after.returning.it.to.
winter.operations.(
)..
.
. If it locks again, request an authorised
service control.
–. Insufficient water pressure (fig..4)
. If. the. “0.5 bar”. red. light. blinks,. the.
module.does.not.work..To.restore.ope-
rations,.fill.the.system.until.the.green.
“1 bar”.led.turns.on..If.all.leds.are.off,.
request.an.authorised.service.call.
–. Safety/exhaust thermostat
triggered (fig..5)
. If. the. safety/exhaust. thermostat. trig-
gers.the.red.“35°C”.led.blinks.
. To. attempt. ignition. again,. rotate. the.
selector.knob.to.( ).and.release.it.im-
mediately. after.
returning.it.to.winter.operations.(
)..
. If it locks again, request an authorised
service control.
–. Other faults (fig..6)
. When. one. of. the. red. “40÷80°C”. leds.
blinks,. turn. off. the. generator. and. at-
tempt.ignition.again..
. This.operation.can.be.repeated.2-3.ti-
mes.at.most,.in.the.event.of.failure,.re-
quest.an.authorised.service.call.
Fig..6
SPIA VERDE
SPIA GIALLA
SPIA ROSSA
SPIA GIALLA INTERMITTENTE
SPIA ROSSA
R E M O T E
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
R E M O T E
SPIA ROSSA INTERMITTENTE
Fig..3
Fig..4
SPIA VERDE
SPIA GIALLA
SPIA ROSSA
SPIA GIALLA INTERMITTENTE
SPIA ROSSA
R E M O T E
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
R E M O T E
SPIA ROSSA INTERMITTENTE
SPIA VERDE
SPIA GIALLA
SPIA ROSSA
SPIA GIALLA INTERMITTENTE
SPIA ROSSA
R E M O T E
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
R E M O T E
SPIA ROSSA INTERMITTENTE
Fig..5
SPIA VERDE
SPIA GIALLA
SPIA ROSSA
SPIA GIALLA INTERMITTENTE
SPIA ROSSA
R E M O T E
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
R E M O T E
SPIA ROSSA INTERMITTENTE
RED.LIGHT
BLINKING.RED.LIGHT
BLINKING.RED.LIGHT
BLINKING.RED.LIGHT.
IN.SAFETY.CONDITIONS
GREEN.LIGHT.
IN.OPERATING.CONDITIONS