2.8
SAFETY KIT
Safety kit assembly is mandatory.
The.kit.code.8101524.supplied.as.option.
for. “DEWY EQUIPE P100-P200-P300-
P400 BOX”.models.it.is.formed.(fig..7):
–..System. supply. flanged. section. code.
6291970
–..System. return. flanged. section. code.
6291968
–..Gaskets,. nuts. and. fastening. screws.
M16
–..Thermometer. 0-120°C. 1/2”. code..
6146004
–..4.5.BAR.safety.valve.code.6042206.and.
drain.funnel.code.6269403
–..Safety.thermostat.100°C.manual.reset.
code.6001409
–..5.BAR.1/4”.water.pressure.switch.max..
code.6037550
–..0.9. BAR. 1/4”. water. pressure. switch.
min..code.6037551
–..Block.pressure.link.code.6291981.and.
bends.code.6291982
–..0-10. BAR. 1/4”. pressure. gauge. code.
6217051,. tap. cod.. 6216606. and. lock.
code.6216650
–..Expansion.vessel.8.liters.code.6245108,.
connection.pipe.code.6227661,.gaskets.
and.nipple.
WARNING: In models “P100-P200-
P300-P400 BOX” the safety kit can be in-
serted in a specific protective case code
8101527 supplied separately.
The.kit.code.8101525.supplied.as.option.
for. “DEWY EQUIPE P500-P600 BOX”.
models.it.is.formed.(fig..7/a):
–..System. supply. flanged. section. code..
6291969
–..System. return. flanged. section. code..
6291971
–..Gaskets,. nuts. and. fastening. screws.
M16
–..Thermometer. 0-120°C. 1/2”. code.
6146004
–..4.5.BAR.safety.valve.code.6042206.and.
drain.funnel.code.6269403
–..Safety.thermostat.100°C.manual.reset.
code.6001409
–..5.BAR.1/4”.water.pressure.switch.code..
6037550
–..5.BAR.1/4”.water.pressure.switch.max..
code.6037550
–..0.9. BAR. 1/4”. water. pressure. switch.
min..code.6037551
–..Block.pressure.link.code.6291981.and.
bends.code.6291982
–..0-10. BAR. 1/4”. pressure. gauge. code..
6217051,. tap. code. 6216606. and. lock.
code.6216650
–..Expansion.vessel.8.liters.code.6245108,.
connection.pipe.code.6227661,.gaskets.
and.nipple.
WARNING: In models “P500-P600 BOX”
the safety kit can be inserted in a spe-
cific protective case code 8101527 sup-
plied separately.
G
M
R
Pmin
Pmax
Fig..7
Capillary assembly
of fuel on/off valve
calibrated to 98°C,
not supplied.
Pmax
Pmin
Fig..7/a
Assembly of the capillary of
the qualified fuel cut off val-
ve, calibrated at 98°C, sup-
plied as option.
ATTENTION: Safety kit
assembly is mandatory.
ATTENTION: Safety kit assembly is mandatory.