Fig. 11
2.10
ELECTRICAL
CONNECTIONS
Each module is supplied with a power cord
which, if replacement is required, must be
ordered from SIME.
230V – 50 Hz single phase voltage is
required using a fuse protected main swit-
ch with at least 3 mm. between contacts.
Observe the L – N polarity and grounding
connection.
NOTE: SIME shall not be liable for any
damages to persons and things due to
lack of boiler grounding.
2.10.1
“DEWY EQUIPE 60 BOX/P60 BOX” wiring diagram
KEY
EV1 Gas valve coil
EV2 Gas valve coil
EA
Ignition electrode
ER
Detection electrode
TS
Safety thermostat 100°C
V
Fan
TPA Water pressure transducer
PI
System pump
SA
Water trap frost sensor
SM
Heating probe
TR
230 – 24V transformer
PD
Differential pressure switch
SV
Fan board
TF
Exhaust thermostat
PA
Air pressure switch
TRA Ignition transformer
RSA Resistance 100 (
Ω
)
R
Resistance*
* The resistance in sequence/cascade installations is supplied in RVA
47 unit kit cod. 8096301/08. Use the resistance according to
module use (Boiler 1,2,3 or 4).
NOTE: Fan control board (SV) “MAX” and “MIN” trim-
mers are sealed and must never be tampered with.
CONNECTOR SPARE PART CODES:
J2
cod. 6278613
J3
cod. 6299971
J4
cod. 6293595
J5
cod. 6293594
J7
cod. 6293593