Normally SIM5215&SIM5216 is mounted on customer host board. Although some ESD components have
been added in SIM5215&SIM5216, to prevent ESD, user should put some ESD components on customers’
board. The ESD components should be placed beside the connectors which human body might touch, such
as SIM card holder, audio jacks, switches, keys, etc. The following table is the SIM5215&SIM5216 ESD
measurement performance; the results are from SIMCom EVB test.
Table 44: The ESD performance measurement table (Temperature: 25
, Humidity:
℃
45%)
Part
Contact discharge
Air discharge
VBAT,GND
±4KV
±6KV
UART,USB
±2KV
±6KV
Antenna port
±4KV
±6KV
Other ports
±2KV
±2KV