Operation
44
users manual inverter SE3.3Ni - SE3.8Ni - SE4.6Ni
3.5 Communication
There are two types of communication methods, RS232 and RS-485 supported in the SE inverters that may be communicated to the external
computer or terminal with RS-232 and/or RS-485 equipped. There is only one type of the communication can be used at a time. User shall
open the front lid to do the selection for the communication function. Figure 2.3.3.1 shows the selection of the communication type by select
the dipswitch in correspondent position on the control board. User should affirm that the dipswitch positions before using the communication
function.
3.6 Explanations of Error Messages
In the event of a fault, the inverter will stop feeding the AC voltage to the mains utility and display the error message on the LCD. Qualified
service personnel shall do the analysis, measurement, and debug if needed according to the error message in order to resume normal
conditions. It is recommended to screen out the fault condition(s) by referring to the table below and then remove the fault condition(s) to put
the inverter return to normal condition and continue to feed AC voltage to the utility steadily. Please contact Siliken Electronics if the same
error message is persistent.
Error Message
Description
GridNA
Drift Fac
VacH
VacL
FacH
FacL
VpvH
Imax AC
No AC voltage is detected on the grid side.
Islanding is detected.
The AC voltage of utility grid is over the upper limit.
The AC voltage of utility grid is under the lower limit.
The frequency of AC voltage of the utility is over the upper limit.
The frequency of AC voltage of the utility is under the lower limit.
The DC voltage of PV array is over the upper limit.
Over current on the AC side.
Содержание SE3.3Ni
Страница 1: ...nverters...
Страница 8: ...ror Messages n ations on 44 44 47 50 50 51 52 53...
Страница 25: ...Installation user s manual inverter SE3 3Ni SE3 8Ni SE4 6Ni 6 Pin Number of the Waterproof RJ 45 plug...
Страница 26: ...25 3 7 Assembly of the Waterproof RJ 45 plug...
Страница 28: ...27 2 4 2 Parallel configuration of inverter incorrect 7...
Страница 56: ...55...
Страница 57: ...Notes user s manual inverter SE3 3Ni SE3 8Ni SE4 6Ni...
Страница 58: ......