AN332
154
Confidential Rev. 0.2
Command 0x57. WB_AGC_STATUS
Returns the AGC setting of the device. The command returns whether the AGC is enabled or disabled. This
command may only be sent when in powerup mode.
Command arguments: None
Response bytes: One
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
1
0
1
0
1
1
1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
SAMEINT
ASQINT
STCINT
RESP1
X
X
X
X
X
X
X
READ_RFAGCDIS
RESP
Bit
Name
Function
1
0
READ_RFAGCDIS
This bit indicates whether the RF AGC is disabled or not
0 = RF AGC is enabled.
1 = RF AGC is disabled.