AN332
Confidential Rev. 0.2
147
Command 0x52. WB_TUNE_STATUS
Returns the status of WB_TUNE_FREQ. The commands returns the current frequency, and RSSI/SNR at the
moment of tune. The command clears the STCINT interrupt bit when INTACK bit of ARG1 is set. The CTS bit (and
optional interrupt) is set when it is safe to send the next command. This command may only be sent when in
powerup mode.
Command arguments: One
Response bytes: Five
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
1
0
1
0
0
1
0
ARG1
0
0
0
0
0
0
0
INTACK
Arg
Bit
Name
Function
1
7:1
Reserved
Always write to 0.
1
0
INTACK
Seek/Tune Interrupt Clear.
If set this bit clears the seek/tune complete interrupt status indicator.
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
SAMEINT
ASQINT
STCINT
RESP1
X
X
X
X
X
X
AFCRL
VALID
RESP2
READFREQ
H
[7:0]
RESP3
READFREQ
L
[7:0]
RESP4
RSSI[7:0]
RESP5
SNR[7:0]