EM358x
Rev. 0.4
199
Bitname
Bitfield
Access Description
TIM_SMS
[2:0]
RW
Slave Mode Selection.
When external signals are selected the active edge of the trigger signal
(TRGI) is linked to the polarity selected on the external input.
000: Slave mode disabled.
If TIM_CEN = 1 then the prescaler is clocked directly by the internal clock.
001: Encoder mode 1. Counter counts up/down on TI1FP1 edge
depending on TI2FP2 level.
010: Encoder mode 2. Counter counts up/down on TI2FP2 edge
depending on TI1FP1 level.
011: Encoder mode 3. Counter counts up/down on both TI1FP1 and
TI2FP2 edges depending on the level of the other input.
100: Reset Mode. Rising edge of the selected trigger signal (TRGI)
>reinitializes the counter and generates an update of the registers.
101: Gated Mode. The counter clock is enabled when the trigger signal
(TRGI) is high. The counter stops (but is not reset) as soon as the trigger
becomes low. Both starting and stopping the counter are controlled.
110: Trigger Mode. The counter starts at a rising edge of the trigger TRGI
(but it is not reset). Only starting the counter is controlled.
111: External Clock Mode 1. Rising edges of the selected trigger (TRGI)
clock the counter.
Note: Gated mode must not be used if TI1F_ED is selected as the trigger
input (TIM_TS=100). TI1F_ED outputs 1 pulse for each transition on TI1F,
whereas gated mode checks the level of the trigger signal.