Powering Off the Enclosure
007-4428-003
27
1.
Apply AC power to the enclosure. Turn the power supply module(s) switch to the
ON position. The green Power Output LED should be lit and the red Fault LED
should be off.
Note:
In a dual-PSU system, it does not matter which PSU is powered on first.
2. All LEDs on the ESI/Ops Panel should be lit green, and the disk drive motors
should start when the enclosure power is activated.
Note:
All LEDs on the ESI/Ops panel should be lit green when power is applied,
which indicates that the system is functioning correctly. If any show amber, then a
problem exists. See Chapter 4 for troubleshooting information.
All drives in the enclosure should automatically start their motors after power is applied.
If this has not occurred, there may be a power problem (a power fault indication would
normally be active).
Powering Off the Enclosure
To power off the enclosure, switch off the power supply modules installed in the
enclosure.