Replacing Power Supply Modules
007-4428-003
33
Replacing Power Supply Modules
Follow these steps to replace a power supply module or a power supply blank module
on the SGI TP900 enclosure:
Warning:
Hazardous voltage and current levels are present inside the storage
subsystem. The replacement of rear-bay modules should only be performed by
technically qualified personnel.
Caution:
Do not remove a module unless a replacement can be immediately added. The
system must not be run without all modules in place.
1.
Switch off the faulty module and disconnect the power supply cord.
Note:
If you have two power supply modules installed, one power supply module
will maintain power to the enclosure while the other module is replaced.
2. Loosen the screws securing the retaining bracket (see Figure 3-1) and slide the
bracket upwards, until it is clear of the side of the power supply module.
Figure 3-1
Power Supply Module Retaining Bracket
FAULT
OUTPUT
GOOD
CHANNEL 2
CHANNEL 1
Retaining bracket