L1 Controller Error Messages
007-4701-003
127
Under certain circumstances a system software or hardware error can occur prior to the
graphics console's ability to display information. In this case you can see the error only
on the L1 controller panel or from an optional system console connected to the Console
serial port on the back of the system. In these cases an error message is displayed on the
L1 display of the form
<geoid> ERR <error code>
or
<geoid> POD <error code>
. Most of the
time, these errors indicate a serious problem and customer service should be called
(please provide the error code to the service representative). See Table 5-3 for a partial list
of the L1 Hexadecimal boot error codes.
Table 5-3
L1 Controller Hexadecimal Boot Error Codes
Error code
Message Meaning or Action Needed
0x80
The unit has no DIMM memory — insure that DIMM group 0 is fully populated. See
the information in “Removing and Replacing Memory DIMMs” on page 107.
0x81
Write to system controller timed out.
0x82
Request for system reset failed.
0x83
Local master arbitration failed.
0x84
No memory available to allocate hardware configuration structure.
0x85
Can’t initialize klconfig.
0x87
Disabled by environment variable.
0x88
Call to unimplemented chip specific function.
0x89
System controller communication initialization failed.
0x8b
Nasid assignment failed
0x8c
Route calculation failed.
0x8d
Critical system controller transaction failed.
0xb0
PAL early self test failed.
0xb1
SAL entered with invalid function code.
0xb2
SAL invoked for firmware recovery.
0xb3
SAL_RESET called with bad parameters.
0xb4
main () returned
0xb5
PAL_CACHE_INFO failed looking for cache to reload.
Содержание Prism
Страница 4: ......
Страница 48: ......
Страница 115: ...Replacing an XG2N Graphics Card 007 4701 003 93 Figure 4 13 Remove XG2N Graphics Board Assembly Rotate board upward ...
Страница 122: ...100 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 18 Installing a Disk Drive B A C D 2 TM ...
Страница 124: ...102 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 19 Removing a Disk Drive A D C B 2 TM ...
Страница 142: ......
Страница 238: ......
Страница 250: ......