4: Installing and Removing Customer-Replaceable Units
Figure 4-24
DIMM Locations (XG2N Module Shown, Others Similar)
6. Install the DIMMs, as follows (see Figure 4-24 and Figure 4-25):
Note:
If you need to find the correct locations in which to install the DIMMs, make
sure to read the introductory material in “Removing and Replacing Memory
DIMMs” on page 107.
a.
Ensure the ejector latches are in the open position (leaning away from the slot).
b. Hold the DIMM only by its edges and remove it from its antistatic package.
c.
Align the bottom edge of the DIMM with the keyed socket.
d. Insert the bottom edge of the DIMM into the socket, and then press down
evenly on the DIMM until it seats correctly. Use extreme care when you install a
DIMM. If you apply too much pressure, you can damage the socket.
e.
When the DIMM is fully seated in the connector, the ejector latches snap into
place flush with each end of the DIMM, see Figure 4-25.
7. Close the top cover as described in “Closing the Cover” on page 80.
Module
DIMM slots
Содержание Prism
Страница 4: ......
Страница 48: ......
Страница 115: ...Replacing an XG2N Graphics Card 007 4701 003 93 Figure 4 13 Remove XG2N Graphics Board Assembly Rotate board upward ...
Страница 122: ...100 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 18 Installing a Disk Drive B A C D 2 TM ...
Страница 124: ...102 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 19 Removing a Disk Drive A D C B 2 TM ...
Страница 142: ......
Страница 238: ......
Страница 250: ......