5: Troubleshooting
ATTN: TEMP # critical temperature reached
@ xxC xxF
The ambient temperature at the module’s air
inlet has exceeded 31 ºC.
ATTN: TEMP # fault temperature reached @
xxC xxF
The ambient temperature at the module’s air
inlet has exceeded 35 ºC.
Temperature stable message:
ATTN: TEMP # stabilized @ xxC/xxF
The ambient temperature at the module’s air
inlet has returned to an acceptable level.
Power off messages:
Auto power down in xx seconds
The L1 controller has registered a fault and is
shutting down. The message displays every
five seconds until shutdown.
Base module appears to have been powered
down
The L1 controller has registered a fault and has
shut down.
Serial number messages:
Brick Serial Number mismatch
See L1 log for details.
System Serial Number mismatch
See L1 log for details.
Invalid System Serial Number format
See L1 log for details.
No assigned System Serial Number
See L1 log for details.
Table 5-2
L1 Controller Messages
(continued)
L1 System Controller Message
Message Meaning and Action Needed
Содержание Prism
Страница 4: ......
Страница 48: ......
Страница 115: ...Replacing an XG2N Graphics Card 007 4701 003 93 Figure 4 13 Remove XG2N Graphics Board Assembly Rotate board upward ...
Страница 122: ...100 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 18 Installing a Disk Drive B A C D 2 TM ...
Страница 124: ...102 007 4701 003 4 Installing and Removing Customer Replaceable Units Figure 4 19 Removing a Disk Drive A D C B 2 TM ...
Страница 142: ......
Страница 238: ......
Страница 250: ......