“hold-up” alarm supposes a direct robbery, where it is better just to activate telephone calls only. The technical
alarm must warn without causing fear.
FALSE ALARM:
Alarm caused by a defect and/or failure of one or more devices (covered by industrial warranty)
IMPROPER ALARM:
Alarm caused by incorrect positioning, technical limit of device and/or random accidental causes independent of
the equipment itself (not covered by industrial warranty).
ALARM partition
Group of detectors, can be armed/disarmed individually or with other groups (partitions A-B-C). The 24-hour
partitions panic-holdup-technological are always armed. The detectors must be appropriately divided among the
various partitions to allow flexibility of use.
ALARM channel
Single location of a specific detector (two in the case of AND) which protects an area, a point, a surface, a
passage. Sometimes the term "zone" is improperly used to indicate a "channel".
AND
Control unit function useful to greatly reduce the probability of improper alarms: two detectors are installed to
protect the same area and/or passage, programming them in AND on the same channel. The alarm will only occur
with the detection of both devices within the pre-established 30 seconds time. If the detectors are the same type
they must be installed opposite; if different type (different technologies) according to logic.
.
ANTI-COERCION
Control panel’s function that allows to disarm the system composing a different code by the usual one, and at the
same time activate silently the emergency telephone calls.
DETECTOR EXCLUSION
Operation which allows to inhibit a detector temporarily (due to failure or other reason) until reset.
HOME AUTOMATION
Electronic/electro-mechanical automation system for activities in the home (lights and household appliances).
TAMPERING
Attempt to open the cases of the appliances of the devices and/or remove them and/or other, with the purpose of
preventing functioning.
EVENTS MEMORY:
Various forms of indelible recording of occurred events, which can have legal value.
PRE-ALARM:
Control panel state prior to actual alarm, caused by detectors programmed with alarm delay or state of the outside
sirens before sounding
RADIO RANGE :
max distance between a transmitter (detectors, key-fobs, keypadss) and a receiver (control panel, sirens). In our
case, because of the low transmission power imposed by the Rules, the radio range can change a lot,
especially inside environments where the position of the transmitter in relation to the receiver is basical. Besides
walls and furniture sometimes create reflections of the radio signals (increasing or reducing the range).
consequently it is necessary to always verify the radio range (readable on the control panel) and to improve it in
the extreme cases: small position changement (more or less 10 centimeters) often allow important
improvements.
ALARM delay:
Time between the detector transmission and the actual alarm: it is adjustable on the Silenya HT control panels
Individually for each detector.
DETECTOR:
Equipment designed to signal an intrusion, passing, open door/window and any other event which poses a danger.
Equivalent term used in the manual: SENSOR
TEST:
Control unit test condition which blocks all sirens and also allows checks and battery replacements.
SECOND PART
– CONTROL PANEL SERENYA MIX GSM
– GENERAL FEAUTURES AND FUNCTIONS
This manual describes the control panel’s feautures and consequently those of the installation: many of these are consequences of the
programming performed during installation. It is the responsibility of the designer and whoever organises the system to agree the functional
aspects with the user, in order to allow effective use, suitable and non-invasive of the peace.
2.1) MAINS OPERATING FEAUTURES
2.1.1) Detectors control:
it’s possible to program up to 50 wireless detectors of any type (up to 100 if programmed in AND).
2.1.2)Three intrusion alarm partitions A-B-C, with different programmable functioning philosophy:
A) Programming with outdoor detectors and consequently Outdoor Alarm Function:
- Zone A is recommended for outdoor intruder detectors: the sirens warn with acoustic signals without ringing at maximum power.
- zone B is recommended for detectors on accesses and zone C for indoor volumetric detectors: both cause GENERAL ALARMS
In this way the user can arm zones A+B when in these places: approach detected by the external sensors is signalled at low volume or with a
vocal message; whenever a protected access is successively forced, the siren is triggered at maximum power.
In the case of improper alarm of the outdoor detectors, the acoustic signals will not be such to disturb, but will remove the
“surprise effect” of
intrusion.
Содержание SERENYA 2000
Страница 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Страница 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Страница 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...
Страница 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...