COPYRIGHT SERENYA
COD. 2001
SERENYA
by Silentron
– made in Italy
B) Traditional programming with all indoor detectors:
In this case all of the detector alarms cause GENERAL ALARM conditions. The intruder detectors can be divided into the three zones A, B, C
depending on the necessity for differentiated arming, considering that the remote controls have the white key that allows to arm zones A+B
automatically and the red key for full arming.
2.1.3) Accessory alarm zones, always active (24/24hrs):
-
“Panic” partition to activate outdoor sirens and telephone calls via a remote control or keypad key in case of need.
-
“Robbery (Hold-up)” partition to exclusively activate telephone calls via a remote control or keypad key in case of need (medical warning also)
-
“Technical” partition to control smoke and water detectors or detectors of any other dangerous event, and set a specific and distinguishable
alarm.
2.1.4) Control panel Arming/Disarming:
- up to 10 bidirectional key-fobs with 4 buttonss for total arming (A+B+C), partial (A+B) and disarming with LED for visual confirmation.
- up to 10 codes of 5 digits for total/partial arming and disarming, to be used on the control panel and keypads, with ANTI-COERCION function.
-
FORCED ARMING: IT’S POSSIBLE TO ARM THE CONTROL PANEL EVERY DAY AT A SPECIFIC PROGRAMMED TIME.
2.1.5) Control unit acoustic signals and alarms (see also "Telephone part")
SERENYA control panels are « speaking », so they give vocal informations recorded in English language
Pre-alarm:
pre-alarm vocal messages or series of "Beeps". Sirenya sirens signals > signal by intermittent acoustic sounds
Outdoor alarm:
external alarm vocal message or series of "Beeps" . Sirenya siren works in “outdoor alarm" mode.
General alarm
: activation of control panel siren and of all sirens (see instructions of the sirens used) provided in the system
Panic alarm with system partially armed or disarmed:
no control unit alarm, but activation of all wireless sirens provided
Robbery alarm:
no control unit alarm, no sirens, but just activation of the “robbery” telephone calls. This control can also be used to
call for a doctor or request other assistance by telephone.
Technological alarm:
intermittent acoustic signal from the control unit for 15 seconds.
Tampering alarm
with system partially armed or disarmed:
intermittent acoustic signal from the control unit for 3 minutes.
Tampering alarm
with system armed:
like general alarm.
Attention! Consider the following aspects:
a) In any case disarming the system will silence the sirens and phone calls. Attention: this control panel has a GSM module that during the
telephone transmission can disturb the attempts of disarming the control panel via key-fob or keypad . In this case disarm the system using the
control panel integrated keypad.
b) During each arming period of partitions A, B, C only three alarms are accepted by each detector (except 24h partition PANIC and HOLD-UP)
in order to avoid that a defective detector becomes a public disturbance. The count re-starts at every arming.
.
2.2) Bidirectional telephone part - Telephone calls
In the installation phase the relevant messages must be recorded/written and connected to telephone numbers to call in the event of alarms: for
example the ALARM will be connected to user, family or friend's numbers, numbers of intervention forces. It is useless to connect the installer's
number to the alarm calls, while it is useful to connect it to the "low battery" calls.
Attention
: the telephone calls to the Police Force require
previous approval, ruled differently from place to place.
This control panel works on the GSM network (mandatory use SIM card). The control panel can transmit up to 6 vocal messages, bound to the
events described here following, calling up to 20 USERS whose the number has been correctly programmed. Before the vocal messages the
correspondent SMS will be sent via the GSM network. Besides there are other already programmed SMS having technical content, that are
transmitted when the event happens. Each of the 20 available phone numbers can be enabled to receive one or more vocal messages and/or
SMS, according to the specific necessities.
2.2.1) VOCAL/SMS MESSAGES TO RECORD/WRITE:
1 - ALARM ZONES A,B,C
: intrusion alarm message generated by detectors programmed on any zone A,B,C. It is possible to select the zones
so as not to transmit the message, for example, outdoor alarm coming from zone A, while the alarms from zones B
and C will be transmitted.
To these messages, either vocal that SMS, is added the position of every detector, if correctly recorded and written
during programming.
2 - TAMPERING
:
message always active, generated by tampering with one or more system devices.
To these messages, either vocal
that SMS, is added the position of every detector, if correctly recorded and written during programming.
3 -
24H PANIC
:
alarm message always active, generated by a manual command, for example yellow key on the remote control.
4 - 24H HOLD-UP
:
alarm message always active, generated by a manual command, for example yellow key on the remote control.
5 - 24H TECHNOLOGICAL
: alarm message always active, generated by a technical alarms detector (smoke, water, gas etc.)
6
– LOW BATTERY
:
alarm message always active, generated by a system component with low battery.
2.2.2) SMS PROGRAMMED IN THE FACTORY
1 = control unit battery flat:
attention!
The system will soon stop functioning!
2 = peripheral battery flat:
attention!
One or more detectors will cease to function shortly (days)!
3 = no supervision and/or presence of radio interference: check the events memory on return
4 = system armed: the message will be only send after an Arming operation realized by remote using a telephone
5 = system disarmed: the message will be only send after a Disarming operation realized by remote using a telephone
6 = 230V power failure and restore
– the message will be send in case of power failure after the programmed time (SETTINGS)
7 = no GSM field for more than 15 min.: the message will be send on return of the GSM field
8 = not available in this model
9 = periodic message of operating status of the control unit: cyclic message every so many hours/days (SETTINGS)
0 = SIM expiry warning message: program (SETTINGS) new expiry in case of pre-paid SIM
Содержание SERENYA 2000
Страница 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Страница 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Страница 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...
Страница 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...