background image

 

COPYRIGHT SERENYA 

COD. 2001 

SERENYA 

by Silentron

 – made in Italy

 

B) Traditional programming with all indoor detectors: 

 

In this case all of  the detector alarms cause GENERAL ALARM conditions. The intruder detectors can be divided into the three zones A, B, C 
depending on the necessity for differentiated arming, considering that the remote controls have the white key that allows to arm zones A+B 
automatically and the red key for full arming. 

 

2.1.3) Accessory alarm zones, always active (24/24hrs): 

 

“Panic” partition to activate outdoor sirens and telephone calls via a remote control or keypad key in case of need. 

“Robbery (Hold-up)” partition to exclusively activate telephone calls via a remote control or keypad key in case of need (medical warning also) 

“Technical” partition to control smoke and water detectors or detectors of any other dangerous event, and set a specific and distinguishable 

alarm. 
 

2.1.4) Control panel Arming/Disarming:

  

 
- up to 10 bidirectional key-fobs with 4 buttonss for total arming (A+B+C), partial (A+B) and disarming with LED for visual confirmation. 
- up to 10 codes of 5 digits for total/partial arming and disarming, to be used on the control panel and keypads, with ANTI-COERCION function. 

FORCED ARMING: IT’S POSSIBLE TO ARM THE CONTROL PANEL EVERY DAY AT A SPECIFIC PROGRAMMED TIME. 

 
2.1.5) Control unit acoustic signals and alarms (see also "Telephone part") 

 
SERENYA control panels are « speaking », so they give vocal informations recorded in English language  

 

 

 

Pre-alarm:

 pre-alarm vocal messages or series of "Beeps". Sirenya sirens signals > signal by intermittent acoustic sounds 

 

Outdoor alarm:

 

external alarm vocal message or series of "Beeps" . Sirenya siren works in “outdoor alarm" mode. 

 

General alarm

: activation of control panel siren and of all sirens (see instructions of the sirens used) provided in the system 

 

Panic alarm with system partially armed or disarmed:

 no control unit alarm, but activation of all wireless sirens provided 

 

Robbery alarm:

 

no control unit alarm, no sirens, but just activation of the “robbery”  telephone calls. This control can also be used to 

call for a doctor or request other assistance by telephone. 

 

Technological alarm:

 intermittent acoustic signal from the control unit for 15 seconds. 

 

Tampering alarm

 

with system partially armed or disarmed: 

 intermittent acoustic signal from the control unit for 3 minutes. 

 

Tampering alarm

 

with system armed: 

like general alarm. 

 

Attention! Consider the following aspects: 

a)  In  any  case  disarming  the  system  will  silence  the  sirens  and  phone  calls.  Attention:  this  control  panel  has  a  GSM  module  that  during  the 
telephone transmission can disturb the attempts of disarming the control panel via key-fob or keypad . In this case disarm the system using the 
control panel integrated keypad. 
b) During each arming period of partitions A, B, C only three alarms are accepted by each detector (except 24h partition PANIC and HOLD-UP) 
in order to avoid that a defective detector becomes a public disturbance. The count re-starts at every arming. 

2.2) Bidirectional telephone part - Telephone calls 

In the installation phase the relevant messages must be recorded/written and connected to telephone numbers to call in the event of alarms: for 
example the ALARM will be connected to user, family or friend's numbers, numbers of intervention forces. It is useless to connect the installer's 
number to the alarm calls, while it is useful to connect it to the "low battery" calls. 

Attention

: the telephone calls to the Police Force require 

previous approval, ruled differently from place to place. 
 
This control panel works on the GSM network (mandatory use SIM card). The control panel can transmit up to 6 vocal messages, bound to the 
events described here following, calling up to 20 USERS whose the number has been correctly programmed. Before the vocal messages the 
correspondent  SMS  will  be  sent  via  the  GSM  network.  Besides  there  are  other  already  programmed  SMS  having  technical  content,  that  are 
transmitted when the event happens. Each of the 20 available phone numbers can be enabled to receive one  or more vocal messages and/or 
SMS, according to the specific necessities. 
 

2.2.1) VOCAL/SMS MESSAGES TO RECORD/WRITE:

 

 

1 - ALARM ZONES A,B,C

: intrusion alarm message generated by detectors programmed on any zone A,B,C. It is possible to select the zones  

 

 

             so as not to transmit the message, for example, outdoor alarm coming from zone A, while the alarms from zones B 

 

 

             and C will be transmitted. 

 

    

To these messages, either vocal that SMS, is added the position of every detector, if correctly recorded and written              

during programming. 

2 - TAMPERING

 :  

message always active, generated by tampering with one or more system devices.

 

To these messages, either vocal 

that SMS, is added the position of every detector, if correctly recorded and written during programming. 

3 -

  

24H PANIC

 : 

alarm message always active, generated by a manual command, for example yellow key on the remote control. 

4  - 24H HOLD-UP

     alarm message always active, generated by a manual command, for example yellow key on the remote control. 

5 - 24H TECHNOLOGICAL

:   alarm message always active, generated by a technical alarms detector (smoke, water, gas etc.) 

– LOW BATTERY

 : 

alarm message always active, generated by a system component with low battery. 

 

2.2.2) SMS PROGRAMMED IN THE FACTORY 

 
1 = control unit battery flat: 

attention!

 The system will soon stop functioning! 

2 = peripheral battery flat: 

attention! 

One or more detectors will cease to function shortly (days)! 

3 = no supervision and/or presence of radio interference: check the events memory on return 
4 = system armed: the message will be only send after an Arming operation realized by remote using a telephone 
5 = system disarmed: the message will be only send after a Disarming operation realized by remote using a telephone  
6 = 230V power failure and restore 

– the message will be send in case of power failure after the programmed time (SETTINGS) 

7 = no GSM field for more than 15 min.: the message will be send on return of the GSM field 
8 = not available in this model 
9 = periodic message of operating status of the control unit: cyclic message every so many hours/days (SETTINGS) 
0 = SIM expiry warning message: program (SETTINGS) new expiry in case of pre-paid SIM 

Содержание SERENYA 2000

Страница 1: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy SERENYA MIX GSM cod 2001 Mixed wired wireless control panel with GSM telephone transmitter ...

Страница 2: ...tions It is mandatory to dispose of accumulators waste batteries according to the Standards in force This is also the case when the devices must be scrapped The batteries must be previously removed returning them to the seller or depositing them in the relevant containers made available by the distribution network If liquid should escape from the batteries use silicone gloves to protect the hands ...

Страница 3: ... 1 2 ARMING DISARMING DEVICES it s possible to program up to 10 key fobs and an unlimited number of keypads look Warning SERENYA control panels can be commanded trought the on board keypad or trought bidirectional key fobs Code 2023 and or trought bidirectional keypads Code 2028 qui confirment les opérations effectuées Soit les télécommandes que les claviers disposent de touches fonction pour acti...

Страница 4: ...en a transmitter detectors key fobs keypadss and a receiver control panel sirens In our case because of the low transmission power imposed by the Rules the radio range can change a lot especially inside environments where the position of the transmitter in relation to the receiver is basical Besides walls and furniture sometimes create reflections of the radio signals increasing or reducing the ra...

Страница 5: ...y arming 2 2 Bidirectional telephone part Telephone calls In the installation phase the relevant messages must be recorded written and connected to telephone numbers to call in the event of alarms for example the ALARM will be connected to user family or friend s numbers numbers of intervention forces It is useless to connect the installer s number to the alarm calls while it is useful to connect ...

Страница 6: ... generating a Tamper alarm disconnect and connect again power supply and begin entering the factory code this operation doesn t delete the realized programming a INSTALLER CODE from 4 to 8 digits which allows access to all programming but not operations b USER CODE from 4 to 8 digits it allows the followings functions placing the control unit in TEST mode for testing or battery change reading the ...

Страница 7: ...ssible tests C1 and C2 identify the received signal level no indication zero Detectors test look remark simulate an alarm condition for every detector individually ALARM det name 03 C1 H C2 H ALARM is the alarm transmission TAMPER in case of tempering A01 is the detector identification if a name hasn t been associated to The other indications are the same of before The quality of the radio signal ...

Страница 8: ...all done KO failed call OC line busy NO no answer READING THE EVENTS WITH CONTROL MANAGEMENT 13 02 09 10 10 INSTAL Date and time of the event INSTAL installer access USAGER USER access GSM no GSM field NUM MOD telephone number changement GSM TEST automatic Restart operation of the GSM module READING THE ALARMS 13 02 09 10 10 ARMED JOHN Date and time of the event ARM total arming ARM AB armed parti...

Страница 9: ...ll press ESC or the button 3 3 10 OTHER FUNCTIONS OF THE CONTROL PANEL Control units with a GSM module offer other automatic functions which can be programmed during installation periodic transmission of control unit operational status SMS GSM models only communication of SIM expiry it is recommended to use SIM without expiry SMS notification of failure and reinstatement of electrical mains power ...

Страница 10: ...ADD NAME PHILIP PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CANC or modify the association numbers messages Using buttons from 1 to 6 PHONE BOOK CONFIRM MEMORY CONFIRM 01 SEARCH POSIT CONFIRM ADD POSITION 01 PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CA...

Страница 11: ...te it only to the number of the interested doctor MSG 5 Attention technical problem at M Rossi s house via Bianchi 10 Turin it will be added fire detector flooding or other depending by the association MSG 6 Attention message from M Rossi s house via Bianchi 10 Turin change the battery the name of the device will be added it will be control panel for the battery of the control panel 4 6 2 VOCAL ME...

Страница 12: ...itions Use 1 2 3 4 5 6 to modify the managed partitions ENTER CODE 4 5 6 7 8 example Enter a 5 digits code 45678 ON A B C MEMOR OFF A B C LABEL CODE 01 _ _ _ _ _ _ _ _ _ _ _ _ _ Write the name of the CODE owner UNDER THREAT N CONFIRM Enable the UNDER THREAT function for the code Y yes or N no VOCAL LABEL TO RECORD Talk close to the microphone Press for all the recording time Verify the remaining t...

Страница 13: ...ways shows the first free position Selecting a previous position the already programmed devices will appear Confirm the one to be modified and procede or delete pressing CANC and re program it 4 9 SETTINGS in this section we can program certain particular functions of the control panel Scroll the different functions using buttons 4 9 1 DETECTOR EXCLUSION EXCL SENSORS CONFIRM A 01 KITCHEN CONFIRM S...

Страница 14: ...tore a missing code cut power supply open the unit tampering alarm and disconnect battery Replace after 10 sec and enter the factory code 0 0 0 0 4 9 9 ANTISCANNER the control unit checks the radio signals in the ether and signals those which interfere with functioning It is possible to set the time of the interference that can be ignored in seconds 1 60 exceeding which the siren is triggered in t...

Страница 15: ...4 9 16 FW VERSION display of the control unit version for any interventions FW VERSION CONFIRM FW VERSION 30155 4 9 17 SYSTEM RESET Confirmation of CANCEL results in the erasing of all the programming performed and of the events memory Be careful before confirming this operation which is irreversible SYSTEM RESET CONFIRM DELETE CONFIRM 4 10 PROGRAMMING THE ALARM DEVICES WIRELESS WARNINGS look spec...

Страница 16: ...5mA in stand by and no wired connections 125mA with backlighting of the display 500mA in alarm Autonomy approx 36 hours with charged battery in stand by and without wired connections To determine the autonomy in the presence of wired connections measure the absorption of the battery without 230V and calculate it correctly Alarm inputs up to 50 instant programmable detectors delayed or AND on 3 arm...

Страница 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Страница 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Страница 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...

Страница 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Отзывы: