The GSM module answers immediately to the incoming calls if the calling number is recognized: in this case we can decide that the telephone 
number has a direct access to the control panel, without the necessity to compose the user code (look 3.8.1). If this is not foreseen, after having 
listened the message, compose on the telephone the user code followed by # and procede with the possibles activations. 

 

3.3.4) - 3.3.5) USER CALLED BY THE CONTROL PANEL 

In case of alarm and phone call, the called person (after having listened to the message repeated twice and the "Beep" of "end of message") 
can block the following calls cycle pressing # on his telephone and/or interact with the device composing the following commands:  

 

 

ARMING/DISARMING:

 

press 0 # to know the control panel status: we’ll have a specific vocal answer. To fully arm the control panel press 0 * 1 #, 

to only arm partitions A+B press 0 * 2 #,  to disarm press 0 * 0 # (

pay attention to don’t procede with this operation in case of real intrusion): 

we’ll have a vocal answer and in the GSM models an SMS confirming the performed operation too. 

 

Local commands:

 entering a number from 1 to 16, followed by * 1 #  we send 1-16 radio commands for the activation of local receivers, 

installed RX (exemple 12 * 1 #). Entering a number from 1 to 16, followed by * 0 #  we send 1-16 radio commands for the deactivation of 
local receivers, installed RX (exemple 12 * 0 #). 

 

3.3.6) REMOTE VARIATION OF MEMORIZED TELEPHONE NUMBERS: 

I

t’s possible to modify telephone numbers programmed in the phone book via SMS using a telephone having telephone number programmed 

with direct access: compose an SMS message preceded by the letter A followed by the numbers without spaces: 
A333555666 (old number to be changed) A333666888 (new number to be programmed) 
The control panel stores the modification and send a confirmation SMS: CHANGE OCCURRED *333666888* 

 

3.3.7) REMAINING SIM CREDIT 

Pressing for 2 seconds the button  

 

 we automatically obtain the remaining SIM credit in vocal format (if the number is programmed - look 4.4).   

 

3.3.8) 

– 3.3.9) REMOTE LISTENING/LIVE VOICE CONVERSATION:  

Wheter the control panel calls a programmed telephone number or the USER calls the control panel, during the connection to the GSM network 
we  can  listen  what  happens  in  the  environments  next  to  the  control  panel  (and  speak  in  case  of  necessity)  pressing  the  button  « * »  on  the 
connected phone keyboard. Pressing it again we stop the listening and we can begin to compose commands. If we don’t do anything for 60 
seconds the connection falls automatically . 
In  the  same  way  we  can  call  using  t

he control panel like a mobile phone: press the button ← for 2 seconds for the connection, compose a 

telephone number within a minute and press 

. To conclude the phone call press ESC or the button 

.  

 

3.3.10) OTHER FUNCTIONS OF THE CONTROL PANEL 

 
Control units with a GSM module offer other automatic functions which can be programmed during installation: 

  periodic transmission of control unit operational status SMS (GSM models only) 

  communication of SIM expiry - it is recommended to use SIM without expiry. 

  SMS notification of failure and reinstatement of electrical mains power supply. 

 

4) FOURTH PART 

– CONTROL PANEL PROGRAMMING 

 

4.1)  GENERAL  NOTES:

 

The  control  panel  programming  is  very  simple  and  is  realized  using  control  panel’s  keypad.  Follow  the  vocal 

instructions and verify programming on the display. To completely understand certain programming parameters read the previous parts of this 
manual. Genaral rules: 
 

 

all programming must be confirmed with the 

 button.  Without confirmation the operation is not valid. 

 

when the display shows symbols such as  



 or 

  upward or downward scrolling or confirmation is possible 

 

when the display shows the letter " Y " (yes) or " N " (no), a specific function may or may not be available.    

 

use the ESC button to exit from a situation; use the CANC button to cancel a programming. 

 

use the 

  button to cancel a part of programming while it is being written. 

 

use the numerical buttons to link or unlink the telephone numbers to the vocal/SMS messages of any kind and select zones A, B, C. 

 

use the numerical buttons to write the hour, date, minutes, seconds wherever required. 

 

Programming errors

: in the case of incorrect entering the device signals the error with 1 or 3 Beeps (remote controls/detectors programming). 

Programming reset

: every programming can be modified/deleted or not confirmed as above described, Otherwise it’s still programmed also in 

case of power failure. The total reset can be done entering in the SETTINGS menù and confirming the "RESET." 
 

Preparation

: it is recommended to program the control panel on the bench, keeping the various satellite devices on hand, which make up the 

system,  sirens  excluded.  Successively,  the  control  unit  and  the  satellites  will  be  positioned  in  the  suitable  positions,  after  checking  the  radio 
range. The various devices must therefore be prepared by opening the battery or accumulator compartment.  

SIM CARD:

 always program the PIN code of the SIM CARD as "1234" or "without PIN" and insert the SIM CARD in the dedicated slot (look 

figures). If the SIM CARD is not in its place,  the message "!SIM" will appear and obviously all the functions depending by the GSM transmitter 
doesn’t work.   

First activation

:

 

Programming can be realized by connecting just the battery: any connection to the mains must be done after definitive fixing of 

the control panel (look electrical connections)

.

 

 

4.2) USER CODE 

– INSTALLER CODE 

 

30154 

The firmware version of the control 

panel will appear. Press 

 , 

choice 

the language using

 

↑↓  

And procede. . . 

 

FACTORY CODE 

0  0  0  0 

 

SET TIME 

10 , 15 

 
 

 

SET DATE 

13 / 02 / 09 

(DD / MM / YY) 

 

USER CODE 

_  _  _  _ 

Insert a 4 digit code (different from 

0000) ; this will be used for USER 

intervention 

 

INSTALLER CODE 

_  _  _  _ 

 

 

 

Содержание SERENYA 2000

Страница 1: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy SERENYA MIX GSM cod 2001 Mixed wired wireless control panel with GSM telephone transmitter ...

Страница 2: ...tions It is mandatory to dispose of accumulators waste batteries according to the Standards in force This is also the case when the devices must be scrapped The batteries must be previously removed returning them to the seller or depositing them in the relevant containers made available by the distribution network If liquid should escape from the batteries use silicone gloves to protect the hands ...

Страница 3: ... 1 2 ARMING DISARMING DEVICES it s possible to program up to 10 key fobs and an unlimited number of keypads look Warning SERENYA control panels can be commanded trought the on board keypad or trought bidirectional key fobs Code 2023 and or trought bidirectional keypads Code 2028 qui confirment les opérations effectuées Soit les télécommandes que les claviers disposent de touches fonction pour acti...

Страница 4: ...en a transmitter detectors key fobs keypadss and a receiver control panel sirens In our case because of the low transmission power imposed by the Rules the radio range can change a lot especially inside environments where the position of the transmitter in relation to the receiver is basical Besides walls and furniture sometimes create reflections of the radio signals increasing or reducing the ra...

Страница 5: ...y arming 2 2 Bidirectional telephone part Telephone calls In the installation phase the relevant messages must be recorded written and connected to telephone numbers to call in the event of alarms for example the ALARM will be connected to user family or friend s numbers numbers of intervention forces It is useless to connect the installer s number to the alarm calls while it is useful to connect ...

Страница 6: ... generating a Tamper alarm disconnect and connect again power supply and begin entering the factory code this operation doesn t delete the realized programming a INSTALLER CODE from 4 to 8 digits which allows access to all programming but not operations b USER CODE from 4 to 8 digits it allows the followings functions placing the control unit in TEST mode for testing or battery change reading the ...

Страница 7: ...ssible tests C1 and C2 identify the received signal level no indication zero Detectors test look remark simulate an alarm condition for every detector individually ALARM det name 03 C1 H C2 H ALARM is the alarm transmission TAMPER in case of tempering A01 is the detector identification if a name hasn t been associated to The other indications are the same of before The quality of the radio signal ...

Страница 8: ...all done KO failed call OC line busy NO no answer READING THE EVENTS WITH CONTROL MANAGEMENT 13 02 09 10 10 INSTAL Date and time of the event INSTAL installer access USAGER USER access GSM no GSM field NUM MOD telephone number changement GSM TEST automatic Restart operation of the GSM module READING THE ALARMS 13 02 09 10 10 ARMED JOHN Date and time of the event ARM total arming ARM AB armed parti...

Страница 9: ...ll press ESC or the button 3 3 10 OTHER FUNCTIONS OF THE CONTROL PANEL Control units with a GSM module offer other automatic functions which can be programmed during installation periodic transmission of control unit operational status SMS GSM models only communication of SIM expiry it is recommended to use SIM without expiry SMS notification of failure and reinstatement of electrical mains power ...

Страница 10: ...ADD NAME PHILIP PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CANC or modify the association numbers messages Using buttons from 1 to 6 PHONE BOOK CONFIRM MEMORY CONFIRM 01 SEARCH POSIT CONFIRM ADD POSITION 01 PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CA...

Страница 11: ...te it only to the number of the interested doctor MSG 5 Attention technical problem at M Rossi s house via Bianchi 10 Turin it will be added fire detector flooding or other depending by the association MSG 6 Attention message from M Rossi s house via Bianchi 10 Turin change the battery the name of the device will be added it will be control panel for the battery of the control panel 4 6 2 VOCAL ME...

Страница 12: ...itions Use 1 2 3 4 5 6 to modify the managed partitions ENTER CODE 4 5 6 7 8 example Enter a 5 digits code 45678 ON A B C MEMOR OFF A B C LABEL CODE 01 _ _ _ _ _ _ _ _ _ _ _ _ _ Write the name of the CODE owner UNDER THREAT N CONFIRM Enable the UNDER THREAT function for the code Y yes or N no VOCAL LABEL TO RECORD Talk close to the microphone Press for all the recording time Verify the remaining t...

Страница 13: ...ways shows the first free position Selecting a previous position the already programmed devices will appear Confirm the one to be modified and procede or delete pressing CANC and re program it 4 9 SETTINGS in this section we can program certain particular functions of the control panel Scroll the different functions using buttons 4 9 1 DETECTOR EXCLUSION EXCL SENSORS CONFIRM A 01 KITCHEN CONFIRM S...

Страница 14: ...tore a missing code cut power supply open the unit tampering alarm and disconnect battery Replace after 10 sec and enter the factory code 0 0 0 0 4 9 9 ANTISCANNER the control unit checks the radio signals in the ether and signals those which interfere with functioning It is possible to set the time of the interference that can be ignored in seconds 1 60 exceeding which the siren is triggered in t...

Страница 15: ...4 9 16 FW VERSION display of the control unit version for any interventions FW VERSION CONFIRM FW VERSION 30155 4 9 17 SYSTEM RESET Confirmation of CANCEL results in the erasing of all the programming performed and of the events memory Be careful before confirming this operation which is irreversible SYSTEM RESET CONFIRM DELETE CONFIRM 4 10 PROGRAMMING THE ALARM DEVICES WIRELESS WARNINGS look spec...

Страница 16: ...5mA in stand by and no wired connections 125mA with backlighting of the display 500mA in alarm Autonomy approx 36 hours with charged battery in stand by and without wired connections To determine the autonomy in the presence of wired connections measure the absorption of the battery without 230V and calculate it correctly Alarm inputs up to 50 instant programmable detectors delayed or AND on 3 arm...

Страница 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Страница 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Страница 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...

Страница 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Отзывы: