MSK500/1
Technical data English
MSK500/1 · Date
11.09.2018 · Art.
No.
81413 · Mod.
status
232/18
30
Maintenance
With correct installation according to chapter
4
the magnetic sensor
requires no maintenance. Clean the surface of the magnetic tape with soft
cloth from time to time if it is very dirty.
Disposal
The magnetic sensor's electronic components contain materials that are
harmful for the environment and are carriers of recyclable materials at the
same time. Therefore, the magnetic sensor must be recycled after it has
been taken out of operation ultimately. Observe the environment protec-
tion guidelines of your country.
9 Technical data
Mechanical data
Additional information
Housing
black plastic
Sensor/band reading dis-
tance
0.1 … 2 mm
O, I reference signals (±2 mm lat-
eral offset)
0.1 … 1.5 mm
R reference signals (±0.5 mm lat-
eral offset)
Sensor/ring reading dis-
tance
0.1 … 2 mm
O, I reference signals (±2 mm lat-
eral offset, ±3° angle offset)
0.1 … 1.5 mm
R reference signals (±0.5 mm lat-
eral offset, ±3° angle offset)
Cable sheath
PUR
6, 8-wire ø5
-0.4
mm
Electrical data
Additional information
Operating voltage
24 V DC±20 %
reverse polarity protected
5 V DC ±5 %
Current consumption
≤70 mA
at 24 V DC; unloaded
Output circuit
PP, LD (RS422)
Output signals
A, A/, B, B/, I, I/, R, R/
quadrature signal
Type of connection
open cable end
plug connector
7/8-pole
D-Sub
9-pole
System data
Additional information
Linearity deviation
±20 µm
at T
U
= 20 °C, reading distance
1 mm
Repeat accuracy
±1 increment(s)
at T
U
= 20 °C