MSK500/1
Installation English
MSK500/1 · Date
11.09.2018 · Art.
No.
81413 · Mod.
status
232/18
24
1
Periodical reference point
2
Position of the reference point
P = as stated in the delivery
documentation
3
Unique reference point
4
Position of the reference point
E = as stated in the delivery
documentation; ≥0.05 m
Fig. 7: Reference point magnetic tape
4.4 Mounting the magnetic ring
Magnetic ring MR500
Slide magnetic ring MR500 onto the shaft and then tighten grub screw M6
to fix it to the shaft.
1. Ensure sliding fit between shaft and MR500.
2. Mount MR500 without force and without strain. Possible forces should
go to the metal flange. Avoid knocks on the magnetic ring.
3. Provide for a relief groove in the solid shaft (see
Fig. 8
).
RADIAL application: MSK500/1 with MR500
1
Direction of outgoing cable
2
Admissible deviation of
ring/sensor
0.1 ... 2 mm reference point
O, I
0.1 ... 1.5 mm reference
point R
3
Direction of rotation of mag-
netic ring signal A before B
4
Reference point
5
Undercut at the solid shaft
for tread plug is recom-
mended
6
Admissable deviation middle
of tape/sensor
ref. O, I ±2 mm
ref. R ±0.5 mm
Fig. 8: Definition of the counting direction with magnetic ring and
assemblage sensor/magnetic ring, gap measure, tolerances
1
2
3
6
4
5
<3°
<3°