MSK500/1
Travel speeds (m/s) English
MSK500/1 · Date
11.09.2018 · Art.
No.
81413 · Mod.
status
232/18
29
6 Travel speeds (m/s)
Resolution (mm) Travel speed Vmax (m/s)
0.005
0.1
0.2
0.4
0.8
1.7
3.4
6.9
13.8
0.01
0.2
0.4
0.8
1.7
3.4
6.9
14.5
25
0.0125
0.3
0.5
1.1
2.2
4.5
9
18
25
0.02
0.4
0.8
1.7
3.4
6.9
14.5
25
25
0.025
0.5
1.1
2.2
4.5
9
18
25
25
0.05
1.1
2.2
4.5
9
18
25
25
25
Pulse interval (μs)
32
16
8
4
2
1
0.5
0.25
7 Trouble shooting
Below are some typical errors which may occur during installation and
operation:
•
Magnetic tape wrongly mounted, active side below (see chapter
4.2
).
•
The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
•
Magnetic sensor not or incorrectly connected (pin assignment see
chapter
4.5
).
•
The distance tolerances were not observed over the whole measuring
length (see
Fig. 6
,
Fig. 8
).
•
Cable squeezed / interrupted / cut by sharp edges.
•
The magnetic sensor has been mounted with the active side turned
away from the band (see
Fig. 6
,
Fig. 8
).
•
Magnetic sensor has not been aligned according to
Fig. 6
,
Fig. 8
.
8 Transport, Storage, Maintenance and Disposal
Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
•
Transport and / or store the magnetic sensor in the unopened origi-
nal packaging.
•
Protect the magnetic sensor from harmful physical influences includ-
ing dust, heat and humidity.
•
Do not damage connections through mechanical or thermal impact.
•
Prior to installation inspect the magnetic sensor for transport dam-
ages. Do not install damaged magnetic sensors.