MSK500/1
Installation English
MSK500/1 · Date
11.09.2018 · Art.
No.
81413 · Mod.
status
232/18
23
4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
Fig. 6
).
1. Mount magnetic tape (see chapter
4.2
).
2. Fasten the magnetic sensor, via the thru-holes (2x ø3.5 mm) on an
even work surface (for the fastening dimensions refer to the Data
Sheet). We recommend to use the enclosed fixing screws and washer
springs (fastening torque 0.25 Nm).
LINEAR application: MSK500/1 with MB500/1
1
Active side magnetic tape
2
Travel direction signal A
before B
3
Direction of outgoing cable
4
Admissible deviation of
tape/sensor
0.1 ... 2 mm reference point
O, I
0.1 ... 1.5 mm reference
point R
5
Maximum alignment error
6
Admissable deviation middle
of tape/sensor
ref. O, I ±2 mm
ref. R ±0.5 mm
7
Position of the reference
point relating to the mark-
ing on the magnetic tape
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
MBxxxx GEK WT RP NNNNNN
<1°
<3°
<3°
NOTICE