MSK210
Installation English
MSK210 · Date
08.02.2018 · Art.
No.
81417 · Mod.
status
41/18
23
1
Periodical reference point
2
Position of the reference point
P = as stated in the delivery
documentation
3
Unique reference point
4
Position of the reference point
E = as stated in the delivery
documentation ≥0.05 m
3
4
1
2
50
Fig. 7: Reference point magnetic tape
4.4 Mounting the magnetic ring
Magnetic ring MR200
Slide magnetic ring MR200 onto the shaft and then tighten grub screw M6
to fix it to the shaft.
1. Ensure sliding fit between shaft and MR200.
2. Mount MR200 without force and without strain. Possible forces should
go to the metal flange. Avoid knocks on the magnetic ring.
3. Provide for a relief groove in the solid shaft (see
RADIAL application
MSK210 with MR200:
1
Direction of outgoing cable
2
Admissible deviation of
ring/sensor
0.1 ... 0.8 mm reference
point O, I
0.1 ... 0.4 mm reference
point R
3
Direction of rotation of mag-
netic ring signal A before B
4
Reference point
5
Undercut at the solid shaft
for tread plug is recom-
mended
6
Admissable deviation middle
of tape/sensor
ref. O, I ±2 mm
ref. R ±0.5 mm
Fig. 8: Definition of the counting direction with magnetic ring and
assemblage sensor/magnetic ring, gap measure, tolerances
1
3
2
6
4
5
<3°
<1°