AG26
Commissioning English
AG26 · Date
03.02.2022 · Art.
No.
87451 · Mod.
status
255/21
37
LED status
Description
green
Operating voltage applied to control, no fault
red, blinks
Operating voltage applied to control, fault active
off
Operating voltage of control missing
Status LED 6, 7
LED statuses valid with factory settings.
LED status
Description
off
no Function
Status LED 8
Supply for the actuator shall be sized sufficiently. When accelerating,
power input may be higher than nominal current for a short period. The
voltage values are a function of the device design and can be referred to in
the technical data in chapter
.
LED statuses valid with factory settings.
LED status
Description
green
Actuator is within the programmed position
window. Supply voltage of the output stage is
applied.
green, blinks Actuator is within the programmed position
window. Supply voltage of the output stage missing.
red
Actuator is outside the programmed position
window. Supply voltage of the output stage is
applied.
red, blinks
Actuator is outside the programmed position
window. Supply voltage of the output stage missing.
off
Operating voltage of control missing
NOTICE