4-2
Repeat the selection of the driving block, input of the pre-heat pulse and input of the main heat pulse to
all blocks.
Figure 4-1 shows the example of timing chart in case of executing previous line history control.
Figure 4-1 Example of timing chart when executing previous line history control
1: When executing previous line history control, the pre-heat pulse data for the next line should not be
transferred until the start of the last main heat driving of the previous line.
2: When executing previous line history control, the main heat pulse data should not be transferred until
the completion of the last main heat driving of the previous line.