2-24
2.6.8 Thermistor Resistance
The resistance of the thermistor at the operating temperature (T
X
°
C) is determined using the following
equation (10).
Equation 10:
R
X
:
Resistance at operating temperature Tx (
°
C)
R
25
:
15 k
Ω
±
10% (25
°
C)
B:
3750 K
±
200 K
T
X
:
Operating temperature (
°
C)
EXP (A):
The Ath power of natural logarithm e (2.71828)
[Rating]
Operating temperature range: -40
°
C to +125
°
C
1 1
R
X
= R
25
×
EXP B
×
-
273 + T
X
298
Figure 2-10 Thermistor Resistance vs. Temperature
TEMPERTURE (
°
C)
R
E
S
I
S
T
A
N
C
E
K
Ω
100
50
40
30
20
10
5
4
3
2
1
0
10
20
30
40
50
60
70
80
90
100
THERMISTOR CHARACTERISTICS