‡ SIGNET
8550-3 Flow Transmitter
Current output:
•
4 to 20 mA, isolated, fully adjustable and reversible
•
Max loop impedance:
50
Ω
max. @ 12 V
325
Ω
max. @ 18 V
600
Ω
max. @ 24 V
•
Update rate: 100 ms
•
Accuracy:
±
0.03 mA
Open-collector outputs, optically isolated:
•
50 mA max. sink, 30 VDC maximum pull-up voltage.
•
Programmable for:
•
High or Low setpoint with adjustable hysteresis
•
Pulse proportional to rate or volume (max 300 pulses/min).
Environmental
•
Operating temperature:
-10 to 70
°
C (14 to 158
°
F)
•
Storage temperature:
-15 to 80
°
C (5 to 176
°
F)
•
Relative humidity:
0 to 95%, non-condensing
•
Maximum altitude:
2000 m (6562 ft)
•
Insulation category:
II
•
Pollution degree:
2
Standards and Approvals:
•
CSA, CE, UL listed
•
Immunity:
EN50082-2
•
Emissions:
EN55011 Class B
•
Manufactured under ISO 9001 and ISO 14001
General
Compatibility: +GF+ SIGNET Flow Sensors (w/freq out)
Accuracy:
±
0.5 Hz
Enclosure:
•
Rating:
NEMA 4X/IP65 front
•
Case:
PBT
Panel case gasket:
Neoprene
•
Window:
Polyurethane coated polycarbonate
•
Keypad:
Sealed 4-key silicone rubber
•
Weight:
Approx. 325g (12 oz.)
Display:
•
Alphanumeric 2 x 16 LCD
•
Update rate: 1 second
•
Contrast: User selected, 5 levels
•
Accuracy:
±
0.5% of reading @25ºC
•
Thermal sensitivity shift:
±
0.005% of reading per ºC
Electrical
•
Power: 12 to 24 VDC
±
10%, regulated, 122 mA max.
Sensor Inputs:
•
Range: 0.5 to 1500 Hz
•
Sensor power:
2-wire: 1.5 mA @ 5 VDC
±
1%
3 or 4 wire: 20 mA @ 5 VDC
±
1%
•
Optically isolated from current loop
•
Short circuit protected
Flow
Flow1: 6.25 GPM
Flow2: 9.75 GPM
ENTER
3-8550.090-3
WARNING!
•
Remove power to unit before wiring input and
output connections.
•
Follow instructions carefully to avoid personal injury.
Contents
1. Specifications
2. Installation
3. Electrical Connections
4. Menu Functions
2.
Installation
ProcessPro transmitters are available in two styles: panel mount and field mount. The panel mount is supplied with the necessary
hardware to install the transmitter. This manual includes complete panel mounting instructions.
Field mounting requires one of two separate mounting kits. The 3-8051 integral kit joins the sensor and instrument together into a
single package. The 3-8050 Universal kit enables the transmitter to be installed virtually anywhere.
Detailed instructions for integral mounting or other field installation options are included with the 3-8051 Integral kit or the 3-8050
Universal kit.
SIDE VIEW
Field Mount w/
8051 Integral kit
SIDE VIEW
Field Mount w/
8050 Universal base
92 mm
(3.6 in.)
97 mm
(3.8 in.)
56 mm
(2.2 in.)
41 mm
(1.6 in.
)
Optional
Rear
Cover
Panel Mount
SIDE VIEW
FRONT VIEW
96 mm
(3.8 in.)
96 mm
(3.8 in.)
Field Mount &
Panel Mount
106 mm (4.2 in.)
42 mm
(1.7 in.)
64 mm
(2.5 in.)
82 mm
(3.23 in.)
8050
102 mm (4.0 in.)
42 mm
(1.7 in.)
60 mm
(2.3 in.)
8051
1. Specifications
Dimensions
F-4/03 English