90 SSG5000A Programming Guide
Example
LFOutput:VOLTage 2 Vpp
LFOutput:VOLTage?
3.5.9.3 LF Offset ([:SOURce]:LFOutput:OFFSEt)
Command Format
[:SOURce]:LFOutput:OFFSEt <volt>
[:SOURce]:LFOutput:OFFSEt?
Instruction
Set the voltage offset of the LF output signal
Get the voltage offset of the LF output signal
Parameter Type
Float, unit: dBm, uV, mV, V, nW, uW, mW, Default: V
Parameter Range
Return
Float, unit: V
Default
0 V
Menu
LF > LF Offset
Example
LFOutput:OFFSEt 1 V
LFOutput:OFFSEt?
3.5.9.4 LF Frequency ([:SOURce]:LFOutput:FREQuency)
Command Format
[:SOURce]:LFOutput:FREQuency <freq>
[:SOURce]:LFOutput:FREQuency?
Instruction
Set LF out put frequency.
Get LF out put frequency.
If the signal source is set to “Internal”, the instrument performs the
analog modulations (AM/FM /PM) with this frequency.
Parameter Type
Float, unit: Hz, kHz, MHz, GHz, Default “Hz”
Parameter Range
0.01 Hz ~ 1 MHz
Return
Float, unit: Hz
Default
1 kHz
Menu
LF > LF Frequency