26 SSG5000A Programming Guide
Setup Type (:SYSTem:PON:TYPE)
Command Format
:SYSTem:PON:TYPE DFT|LAST
:SYSTem:PON:TYPE?
Instruction
Sets the signal generator power on state. Default is the factory
configuration and last recalls all of the settings used before the last
power down.
Get power on type.
Parameter Type
Enumeration
Parameter Range
DFT|LAST
DFT: Default
LAST: Last
Return
Enumeration
Default
DFT
Menu
Utility > Setting > Setup Type
Example
:SYSTem:PON:TYPE DFT
:SYSTem:PON:TYPE?
Power On Line (SYSTem:POWeron:TYPE)
Command Format
SYSTem:POWeron:TYPE ON|OFF|1|0
SYSTem:POWeron:TYPE?
Instruction
Set the signal generator power on line state.
Get the signal generator power on line state.
Parameter Type
Boolean
Parameter Range
ON|OFF|1|0
Return
Boolean
Default
OFF
Menu
Utility > Setting > Power On Line
Example
SYSTem:POWeron:TYPE ON
SYSTem:POWeron:TYPE?