SSG5000A Programming Guide 105
Average Times (:SENSe[:POWer]:FILTer:LENGth)
Command Format
:SENSe[:POWer]:FILTer:LENGth <length>
:SENSe[:POWer]:FILTer:LENGth?
Instruction
Set the average number times
Parameter Type
Integer
Parameter Range
Limit by power sensor
Return
Float
Default
None
Menu
SENSOR > Averaging
Example
SENSe:FILTer:LENGth 10
SENSe:FILTer:LENGth?
Internal Noise (:SENSe[:POWer]:FILTer:NSRatio)
Command Format
:SENSe[:POWer]:FILTer:NSRatio <noise>
:SENSe[:POWer]:FILTer:NSRatio?
Instruction
The power sensor will control the internal noise that does not exceed
the set value of the fixed noise parameter
Parameter Type
Float, unit: dB
Parameter Range
Limit by power sensor.
Return
Float, unit: dB
Default
None
Menu
SENSOR > Averaging
Example
SENSe:FILTer:NSRatio 1
SENSe:FILTer:NSRatio?
Содержание SSG5080A Series
Страница 1: ...SSG5080A Series Signal Generator Programming Guide PG0805A E01A ...
Страница 2: ......
Страница 124: ...122 SSG5000A Programming Guide ...
Страница 136: ......