Administration
Rev 4 May.17
57
11.9 Accessing the Console
Additional administration of the oMG can be performed by connecting the
gateway to a laptop that is running a terminal emulator such as PuTTY. The
connection requires a straight-through (i.e. non-null modem) DB-9 serial cable
between the oMG and laptop, and the following settings must be configured on
the oMG via the LCI:
1.
Navigate to the Devices > Serial tab and ensure that Use is set to Application.
2.
Navigate to the GPS tab and locate the Local Forwarding sub-section.
3.
Turn on the RS-232 checkbox under the Serial settings and apply the
following settings:
·
Speed (baud): 115200
·
Data bits: 8
·
Stop bits: 1
·
Parity: None
·
StopBitX2: 1
·
HW Flow: XON/XOFF
4.
Click Submit.
5.
Connect the oMG to a laptop using the DB-9 cable and proceed to run
PuTTY.