6.5 Not connected to the OCPP server, not reporting software firmware
version/serial number
Two conditions can cause this issue: 1. OCPP server outage or; 2. Wi-Fi Module malfunction.
VersiCharge not connecting to the OCPP server, not reporting software firmware version/serial number
OCPP server outage
1
IF
VersiCharge is not communicating, it may be due to an OCPP server outage. Notify Customer Service of the outage.
2
THEN
Try again later.
Troubleshooting the Wi-Fi module
1
Turn the breaker to the VersiCharge to OFF.
2
Open the front cover of the VersiCharge.
Troubleshooting the Wi-Fi module
3
Slide the Wi-Fi Module out of the channel and reseat firmly in channel.
4
Turn the breaker to the VersiCharge to ON; allow time for the VersiCharge reboot.
5
Check Wi-Fi Status light.
6
IF
The VersiCharge is not communicating (Wi-Fi Status not lit),
7
THEN
Call customer service for further instructions.
8
IF
The VersiCharge is communicating (Wi-Fi Status is green or amber)
9
THEN
The Wi-Fi Module is communicating, and cloud connection is possible.
Note: If a new Wi-Fi Module has been provided by Siemens, recommission the VersiCharge by unlinking the charger from the cloud, and
follow the commissioning instructions (see 9. Commissioning, below).
6.6 Charger offline/not connected to the VersiCharge SG cloud
•
See
5.1
and
5.5
above.
• Note: be aware of network extenders.
24
VersiCharge™ SG
Commissioning and Troubleshooting Guide