Page 26
Copyright
2011 Siemens Industry, Inc.
141-00015, Rev 01
Technical Specifications
Siemens SMIINV215R60XX Microinverter Operating Parameters
Topic
Unit
Min
Typical
Max
DC Operating Parameters
MPPT voltage range
V
22
29
36
Operating Range
V
16
36
Maximum DC input voltage
V
45
Minimum / Maximum start voltage
V
22
45
Maximum DC input short circuit current
A
15
Maximum DC input current
A
10.5
Ground fault protection
mA
1000
Maximum input source backfeed current to input source
A
0
AC Operating Parameters
Maximum AC output Power (-40 to 65
°
C)
W
215
Output power factor
0.95
0.99
1
Nominal AC output voltage range
240 Vac
208 Vac
Vrms
Vrms
211
183
240
208
264
229
Extended AC output voltage range
240 Vac
208 Vac
Vrms
Vrms
206
179
240
208
269
232
Maximum AC output current
240 Vac
208 Vac
A
A
0.9
1.0
Nominal AC output frequency range
Hz
59.3
60
60.5
Extended AC output frequency range
Hz
59.2
60
60.6
Maximum AC output over current protection
A
20 A
Maximum AC output fault current & duration
A
peak
, ms
25.2 A
peak
over 1.74 ms
A
RMS
, Cycles
1.05 A
RMS
over 3 cycles
1.04 A
RMS
over 5 cycles
High AC Voltage trip limit accuracy
%
±
2.5
Low AC Voltage Trip limit accuracy
%
±
4.0
Frequency trip limit accuracy
Hz
±0.1
Trip time accuracy
ms
±33