Weighing
Functions
5.7.1
DS 30 – Scale Status
The status information provides details of the current state of the scale.
Bit No.
Name
Range of Values / Meaning
0
Limit value 1
1 = Limit value 1 has responded
1
Limit value 2
1 = Limit value 2 has responded
2 Scale
tared
1 = Tare memory occupied (
≠
0)
3 Preset
tare
1 = Tare memory contains ext. default value
4 Max+9e
1 = Gross weighing range exceeded or undershot by more than 9 display steps
5 ¼d
zero
1 = Gross less than ± 0.25d (d corresponds to set numeral step)
6 Standstill
1 = Standstill exists
7 Module
adjusted
1 = Module adjusted
8 Parameter
definition
blocked
1 = Write protect switch active;
(No adjustment parameter DS3 or adjustment commands can be sent)
9 Min.
weighing
range
undershot
1 = Min. weighing range undershot
10 --
--
11 --
--
12 --
--
13 --
--
14 Booting
The SIWAREX module is starting up
15
Module group fault
1 = Global module fault / operating error (SF)
Table 5-7
Status information
5-32 SIWAREX
MS