FEC920: USER GUIDE
Appendix A
Page 209
A5e38775501-AA
September 18
A2 RECORDER SPECIFICATION
I/O
types
Analog i/p
Four (eight if dual input option fitted)
Digital i/p
Two
Digital (logic) o/p
See Table A1 for options
Relay o/p
See Table A1 for options
DC output
See Table A1 for options
Features
CSV archive format
EtherNet/IP (Option)
File transfer protocol (FTP)
Modbus Master (Option)
Modbus TCP slave
uhh (history file) archiving
USB port at rear of instrument
User linearization tables (four)
15 Virtual channels (each configurable as maths,
totalizer or counter).
30 Virtual channels if Modbus Master or EtherNet/IP
options fitted (no alarms on virtual channels 16 to 30)
Environmental performance
Ambient temperature range
Operating:
0 to 55°C (32 to 131°F)
Storage:
-20 to +70°C (-4 to 158°F)
Humidity range
Operating:
5% to 85% RH non condensing
storage:
5% to 85% RH non condensing
Protection
Front panel (Standard):
IP65
Front panel (Wash down):
IP66, NEMA12
Behind panel:
IP10 (International)
Shock/Vibration
To BS EN61131-2 (5 to 150Hz. at 1g; 1 octave per min.)
Altitude
<2000 metres (6561.7ft)
Atmosphere
Not suitable for use in explosive or corrosive atmospheres.
Electrical safety
BS EN61010-1 (Installation category II; Pollution degree 2)
Electromagnetic compatibility
Emissions (standard units):
BS EN61326 Class B - Light industrial.
Emissions (Low voltage option):
BS EN61326 Class A - Heavy industrial
Immunity
BS EN61326 Industrial
Other approvals and compliance details
General:
CE and cUL, EN61010
PV input
AMS2750E compliant
RoHS
EU; China
Packaging
BS EN61131-2 section 2.1.3.3.
Physical
Panel mounting
1/4 DIN
Weight
0.44kg (15.52 oz.)
Panel cutout dimension
92mm x 92mm (both -0.0 +0.8) or 3.62in x 3.62in (both -0.00 +0.03 in) (Figure 2)
Depth behind panel
90mm (3.54in) (Figure 2) excluding wiring.
Operator interface
Display
3.5” TFT color display (320 pixels wide x 240 pixels high)
Controls
Four navigation pushbuttons below the display screen (Page, Scroll, Lower and Raise)
Power requirements
Supply voltage
Standard:
100 to 230Vac ± 15% at 48 to 62Hz.
Low voltage option:
24Vac (+10% - 15%), at 48 to 62Hz, or 24Vdc (+20% -15%)
Power dissipation
9W
Fuse type
None
Interrupt protection
Standard:
Holdup >20ms at 85V RMS supply voltage.
Low voltage option:
Holdup >20ms at 20.4V RMS supply voltage.
Battery backup
Stored data
Time, date.
Support time (for real-time clock)
Minimum of 1 year with unit unpowered.
Replacement period
Three years typical
Type
poly-carbonmonofluoride / lithium (BR2330) (PA260195)
Ethernet communications
Type:
10/100Base-T Ethernet (IEEE802.3)
Protocols:
Modbus TCP/IP slave, FTP, DHCP
Cable type
Category 5
Maximum length
100metres (110 yards)
Termination
RJ45. Green LED illuminated = link connected; Amber LED flashing shows link activity.
USB port
Number of ports
One at rear of instrument
Default
Options
Table A1 Output options
L = Logic output; R = Relay; D = DC output
OP4 and OP5 share Common terminals.