5. Connect ground to terminal and power to terminals L/+ and N/- in the manner shown
below at right using a screwdriver.
)
①
L/
+
②
N/
-
③
Protective Earth (PE)
AC connection
DC connection
/
1
/
1
/
Power: 100 to 240 V AC, 47 to 63 Hz
/
1
/
Power: 19.2 to 28.8 V DC
6. Mount power supply protection cover and fasten protection cover screw.
7. Tighten cable gland.
5.2.2.10
Finishing the transmitter connection
Connection check-up
1. Check individual wire installation by tugging firmly.
2. Firmly tighten cable glands and insert blanking plugs in unused cable entries.
3. Close lid.
4. Tighten the four spring screws.
5. Ensure that moisture does not penetrate to inside of electronics enclosure.
Connecting
5.2 Connecting FC430
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
85
Содержание SITRANS FC430
Страница 40: ...Description 3 5 Theory of operation FC430 From firmware 4 0 40 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 94: ...Connecting 5 4 Device nameplates FC430 From firmware 4 0 94 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 150: ...Operating FC430 7 2 HMI FC430 From firmware 4 0 150 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 182: ...Functions 8 16 Maintenance FC430 From firmware 4 0 182 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 262: ...Dimensions and weight 12 5 Mounting bracket FC430 From firmware 4 0 262 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 534: ...Index FC430 From firmware 4 0 534 Operating Instructions 06 2017 A5E39789392 AA ...